COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 28,1995 PSA#1292Coastal Systems Station, Dahlgren Division, NSWC, Panama City, FL
32407-7001 70 -- 4 EA RUGGEDIZED COMPUTERS IN ACCORDANCE WITH THE SPECIFICATIONS
LISTED IN ITEM 17 SOL N61331-95-R-0023 DUE 022495 POC James McCaffery,
Contract Specialist, (904)235-5910, Mary G. Clark, Contracting Officer,
(904)234-4314. The Coastal Systems Station Dahlgren Division, NSWC is
soliciting proposals for a firm fixed price contract to provide four
(4) ruggedized computers. This solicitation is a 100% small business
set aside. The computers must meet the following performance
requirements: (a) Computer Processor: Intel 80486 25MHz or faster. (b)
Memory: Must have at least 4MB RAM. (c) Environmental: Must operate
during 2 Gs, 50 to 2000Hz and meet MIL-STD-167-1, Type 1, and 10 Gs,
half sine wave for 11ms. Computer must also meet MIL-STD-108L for drip
proof operation. Must meet MIL-STD-810 for ruggedization. (d) Chassis:
Must be ruggedized body made of non permeable, crush proof material
with the ability to hold and protect additional cards as may be added.
Must come with one extra frame, if frames are required. Must filter
the air being used to cool the computer. Must close at front with
keyboard and at the rear must close for protection of rear mounted
connectors. (e) Expansion Bus: The expansion bus shall have at least 6
accessory slots of which 4 are 16 bit and 2 are 8 bit, card edge
connectors shall conform to as a minimum industry standard architecture
(ISA). (f) Operating System: MS-DOS version 6.22 or higher and windows
3.11 or higher. (g) Compatibility: Must be compatible with all major
software written for the MS-DOS IBM at and higher computer. Must be
fully MS-DOS compatible. (h) Storage Devices: Must have one (1) 1.44MB
3.5 inch FDD. Must have one (1) 100MB or better ruggedized removable
hard disk drive in bay and a second hard drive of the same type as a
back up unit. Only one docking bay is required. (i) Interfaces: Must
have at least one (1) RS-232C port. Must have at least one parallel
port, and a keyboard connector. (j) Display: Will be built in VGA or
better electro-luminescent display of at least 9'' when measured
diagonally. (k) Keyboard: Must have a ruggedized industry stand 101-key
keyboard with a cable of at least eighteen (18) inches in length, must
have built in trackball for use with windows 3.11 or better. (l)
Weight: One man lift, not more than 40 lbs total weight. (m) Size:
Counter top configuration, not to exceed 20'' by 10.0'' by 25.0''. (n)
Power: Must operate on 110 to 240VAC and 50 to 400 Hz power. Must have
a minimum 200 watt switching power supply. (o) Humidity: Operating: 95%
maximum (no condensation) Non-Operating: 100%. (p) Temperature Range:
Must be capable of operating in temperatures ranging from -10 degrees
(c) to +55 degrees (c), with no degrading of performance. Non-Operating
computer must survive from -55 degrees (c) to +71 degrees (c). Direct
expressions of interest in obtaining this solicitation in writing
should be addressed to Mr. James McCaffery, Code SC12, Coastal Systems
Station, 6703 West Highway 98, Panama City, FL 32407-7001. No
telephone requests will be accepted. Note 1 applies. (0055) Loren Data Corp. http://www.ld.com (SYN# 0293 19950227\70-0002.SOL)
70 - General Purpose ADP Equipment Software, Supplies and Support Eq. Index Page
|
|