COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 9,1995 PSA#1280Coastal Systems Station, Dahlgren Division, NSWC, Panama City, FL
32407-7001 66 -- SPECTROMETERS - EXTREL CORPORATION'S BRAND NAME OR EQUAL SOL
N61331-95-R-0022 DUE 032995 POC Mary Kitchen, Contract Specialist,
(904)235-5389 Carol A. Dreger, Contracting Officer, (904)234-4863. The
Coastal Systems Station, NSWC, DD, intends to procure for the Navy
Experimental Dive Unit two (2) 3/4 inch, high transmission, high
resolution, quadrupole process mass spectrometers on a
brand-name-or-equal basis. Manufacturer and model information is as
follows: Extrel Corporation MS-250 Multi-purpose Gas Analyzer with
QUESTOR IV SMARTools(tm), QUICKstick(tm) Vacuum Option with Iridium
Filaments, 16-Port Rotary Valve, MS-250 Power Station, SMARTlink(tm),
Fast Acquisition Software, 8-Channel Analog Output, Applications
Engineering, Vacuum Chamber Pressure Display, and start-up service.
Salient characteristics are: Breath to Breath analysis, as measured
from 0 to 90% of full scale, in 50 milliseconds or less per component
with proven respiratory analysis by the U.S. Navy (references
required), Microsoft Windows(tm) based computer control system
installed on a 486 DX2/66 computer (as further defined), Turbomolecular
pumped, capable of processing gases in both high Nitrogen (plus or
minus 79%) and high Helium (plus or minus 98%) background, on-line
support via high speed modem for system support, diagnostics and
troubleshooting, availability of consumables within 24 hours, capable
of scanning from 1 to 250 atomic mass units (amu) for trace
contaminants for extended chamber monitoring, dual filaments capable of
being switched without equipment shutdown or process interruption other
than to switch, 16-port rotary valve, vacuum chamber pressure display,
analog outputs for a minimum of eight (8) selected components,
multi-level alarm capability (two high and two low per component),
capability to monitor up to 40 components and 64 masses for chamber
monitoring of divers with a detection limit of 10 parts per million
(ppm) and a dynamic range from 10 ppm to 100%. Delivery is to be by 24
July, 1995. This solicitation is full and open competition. A single
award will result from this solicitation. No telephone requests will be
accepted. Only written requests for this solictiation will be accepted.
However, we will accept requests for this solicitation via facsimile,
at (904)234-4251, Attn: Mary Kitchen, Code SC12. All requests should
include the company's cage code. (0038) Loren Data Corp. http://www.ld.com (SYN# 0411 19950208\66-0002.SOL)