Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF SEPTEMBER 10, 2026 SAM #9054
SOLICITATION NOTICE

Z -- REPAIR LIVE FIRE TRAINING FACILITY AIRCRAFT MOCK-UP

Notice Date
9/8/2026 12:00:00 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
FA6656 910 AW LGC YNGSTN WRN ARPT VIENNA OH 44473-0910 USA
 
ZIP Code
44473-0910
 
Solicitation Number
FA665626R0006
 
Response Due
9/21/2026 7:00:00 AM
 
Archive Date
10/06/2026
 
Point of Contact
Joseph Perry, Phone: 3306091212, Joshua D Indorf, Phone: 3306091389
 
E-Mail Address
joseph.perry.14@us.af.mil, joshua.indorf.1@us.af.mil
(joseph.perry.14@us.af.mil, joshua.indorf.1@us.af.mil)
 
Small Business Set-Aside
WOSB SBA Certified Women-Owned Small Business (WOSB) Program Set-Aside (FAR 19.15)
 
Description
The 910th Airlift Wing requires repair and corrective work to the Aircraft Fire Training Facility (AFTF) aircraft mock-up located at Youngstown Air Reserve Station. An inspection and evaluation of the Aircraft Fire Training Facility was conducted in August 2025 and finalized in April 2026. The assessment identified deficiencies affecting the facility's burner and ignition systems, structural components, corrosion protection, sprinkler system, propane distribution and emergency shutoff systems, control systems, and associated components. The contractor shall furnish all labor, supervision, materials, equipment, tools, transportation, testing, quality control, and other items and services necessary to complete the work identified in the Statement of Work, drawings, specifications, and solicitation attachments. Troubleshooting, repair, and/or replacement of the Tail Engine Burner, Wheel Well Burner, Flight Deck Burner, and Cargo Area Burner and associated ignition systems. Repair or replacement of burner ignition components as required to restore proper operation. Replacement of the malfunctioning cargo-area sprinkler head and restoration of proper drainage functionality. Structural steel repairs and corrosion remediation beneath portions of the aircraft mock-up. Corrosion repair beneath flight-deck stairs and around door assemblies. Repair and/or replacement of the warped R2 door and warped grating near the cargo-fire area. Certified welding and associated aircraft mock-up repairs. Installation/restoration of an emergency energy shutoff capability at the propane storage area. Installation of required solenoid valve(s) in the LPG/propane distribution system. Correction of deficiencies involving legacy pneumatic shutoff valves. Required control-system repairs/upgrades. Associated maintenance, testing, and corrective actions necessary to provide a complete and functional system. Applicable standards identified in the Government's technical documentation include, as applicable: USAF Technical Order 35E1-2-13-1 NFPA 54 NFPA 58 NFPA 70 NFPA 1003 NFPA 1402
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/53dbe200efa641bd84761a010c66de63/view)
 
Place of Performance
Address: Vienna, OH 44473, USA
Zip Code: 44473
Country: USA
 
Record
SN07961017-F 20260910/260908230048 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.