Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF AUGUST 13, 2026 SAM #9026
SOURCES SOUGHT

61 -- Motor Control Panels

Notice Date
8/11/2026 12:00:00 AM
 
Notice Type
Sources Sought
 
NAICS
335314 — Relay and Industrial Control Manufacturing
 
Contracting Office
W072 ENDIST PITTSBURGH PITTSBURGH PA 15222-4198 USA
 
ZIP Code
15222-4198
 
Solicitation Number
W911WN26QA061
 
Response Due
8/20/2026 7:00:00 AM
 
Archive Date
09/04/2026
 
Point of Contact
Lisa Bisnette, Phone: 4123957556, Richard Mathena
 
E-Mail Address
lisa.d.bisnette@usace.army.mil, richard.a.mathena@usace.army.mil
(lisa.d.bisnette@usace.army.mil, richard.a.mathena@usace.army.mil)
 
Small Business Set-Aside
SBA Small Business Set Aside - Total
 
Description
SOURCES SOUGHT NOTICE Motor Control Panels Solicitation Number: W91WN26QA061 Notice Type: Sources Sought / Market Research NAICS Code: 335314 � Relay and Industrial Control Manufacturing PSC Code: 6110 � Electrical Control Equipment Small Business Size Standard: 750 employees 1. Purpose The U.S. Army Corps of Engineers (USACE), Pittsburgh District, is conducting market research to identify small business concerns that are interested in and capable of performing the requirement described below. This Sources Sought Notice is for market research and acquisition planning purposes only. It is not a solicitation, Request for Quotation (RFQ), or Request for Proposal (RFP), and no contract will be awarded as a result of this notice. The information received will assist the Government in determining the appropriate acquisition strategy, including whether the requirement should be set aside for small business concerns. 2. Requirement Description The Government anticipates a requirement to engineer, design, fabricate, test, and deliver sixteen (16) replacement motor control panels for the following USACE Pittsburgh District facilities: Hildebrand Lock and Dam � 6 EA Morgantown Lock and Dam � 6 EA Opekiska Lock and Dam � 4 EA The new panels shall replace the existing motor control panels in kind, operate identically to the existing systems, and integrate with existing wiring and remote gate-control systems. The requirement includes field verification at all three facilities, engineering and design, preparation of electrical schematics and panel layouts, component selection, fabrication, factory acceptance testing, documentation, and delivery. Major requirements include: Stainless steel 304 or 316 National Electrical Manufacturers Association (NEMA) Type 4X/IP66 enclosures 480 VAC, three-phase power with ground Circuit breakers, fuses, overloads, power supplies, power distribution blocks, relays, contactors, terminal blocks, transformers, and associated wiring Field verification of dimensions, existing wiring, terminal-block locations, and site conditions Comprehensive design package for Government approval prior to fabrication Fabrication by an Underwriters Laboratories (UL) 508A-approved panel shop Factory acceptance testing Delivery of all sixteen panels within approximately 240 calendar days after contract award 3. Capability Information Requested Interested small business concerns shall provide a brief capability statement addressing the following: Company name, address, Unique Entity Identifier (UEI), and Commercial and Government Entity (CAGE) Code. Business size and socioeconomic status under NAICS 335314. Confirmation that your company is interested in this requirement and intends to submit a quotation if a solicitation is issued. Confirmation that your company can engineer, design, fabricate, test, and deliver all sixteen motor control panels. Confirmation that the panels will be fabricated by a UL 508A-approved panel shop. Provide the applicable UL file number. A brief description of relevant experience designing and fabricating similar industrial motor control panels, including at least one example of a similar project. Confirmation that your company can perform field verification at Hildebrand, Morgantown, and Opekiska Locks and Dams. Confirmation that your company has experience integrating replacement control panels with existing 480 VAC, three-phase electrical and control systems. Whether your company can reasonably meet the anticipated 240-calendar-day delivery requirement. Any concerns or recommendations regarding the technical requirements, delivery schedule, or other factors that may affect competition. Brochures or general marketing materials may be provided but should be supplemented with information that specifically addresses the capabilities listed above. 4. Response Instructions Responses shall be submitted electronically to: Lisa Bisnette Contract Specialist U.S. Army Corps of Engineers, Pittsburgh District Email: Lisa.D.Bisnette@usace.army.mil Responses are due no later than 10:00 a.m. Eastern Time on Thursday, August 20, 2026. Please include �Sources Sought � Motor Control Panels� in the subject line. 5. Disclaimer This Sources Sought Notice does not constitute a solicitation and does not obligate the Government to issue a solicitation or award a contract. Respondents will not be reimbursed for any costs associated with preparing or submitting a response. The Government may use the information received to determine the appropriate acquisition and small business strategy. Failure to respond to this notice does not preclude participation in any future solicitation, if issued.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/4b9db8c7730d426ca5def108aa71aa5b/view)
 
Place of Performance
Address: Morgantown, WV 26501, USA
Zip Code: 26501
Country: USA
 
Record
SN07922845-F 20260813/260811230055 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.