Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF AUGUST 13, 2026 SAM #9026
SPECIAL NOTICE

65 -- IsoPoint System and Software Intent to Sole Source

Notice Date
8/11/2026 12:00:00 AM
 
Notice Type
Special Notice
 
NAICS
334517 — Irradiation Apparatus Manufacturing
 
Contracting Office
252-NETWORK CONTRACT OFFICE 12 (36C252) MILWAUKEE WI 53214 USA
 
ZIP Code
53214
 
Solicitation Number
36C25226Q0657
 
Response Due
8/18/2026 2:00:00 PM
 
Archive Date
08/23/2026
 
Point of Contact
Stacy Massey, Contracting Officer, Phone: 4148448400
 
E-Mail Address
Stacy.Massey@va.gov
(Stacy.Massey@va.gov)
 
Description
Intent to Sole Source The Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 12 in Milwaukee, WI, intends to award a firm fixed price purchase on a sole source basis to: AKTINA CORP. 360 N ROUTE 9W CONGERS, NY 10920-1420 This action is for the acquisition of the isoPoint Isocenter Characterization System. This procurement supports the Clement J. Zablocki VA Medical Center, Stereotactic Radiosurgery (SRS) Program, located at 5000 W. National Avenue, Milwaukee, WI 53295. This notice of intent is not a request for competitive proposals. No solicitation document is available, and no request for quotes will be issued. The Government requires the isoPoint Isocenter Characterization System, a proprietary optical tracking and 3D mechanical isocenter analysis solution used for precision quality assurance of stereotactic radiosurgery operations. The system consists of: Stereo camera pod Tracking modules Precision mechanical markers Software capable of 3D characterization, mechanical axis assessment, collimator and couch analysis, and beam to target error computation The isoPoint system will enhance the accuracy and efficiency of quality assurance for the facility s Elekta Versa HD LINAC, providing real time 3D mechanical data not achievable through existing Winston Lutz methodologies. The system s capability to achieve sub 0.01 mm mechanical precision is critical to maintaining clinical standards for the SRS program. Aktina Medical is the sole manufacturer and exclusive provider of the isoPoint Isocenter Characterization System. The isoPoint is the only known system capable of conducting direct mechanical rotational axis measurements of LINAC subsystems and generating a full 3D error matrix. Other QA tools rely on image based estimation and lack the ability to perform subsystem specific mechanical characterization. Only Aktina Medical s isoPoint system meets the clinical, technical, and operational requirements necessary to safely support the facility s stereotactic radiosurgery program. Interested parties may submit a capability statement that demonstrates the ability to provide an item equal to or exceeding the functional characteristics of the required isoPoint system. Responses must include: Technical specifications showing equivalency Proof of manufacturing authorization Evidence of ability to meet sub 0.01 mm mechanical precision and full 3D mechanical axis characterization Delivery and installation capability Responses are due: August 18, 2026 at 5:00pm Email responses to: Stacy.Massey@va.gov Include: Intent to Sole Source isoPoint in the subject line. No telephone inquiries will be accepted. If no responses meeting the Government s requirements are received, the VA will proceed with the sole source procurement.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/e211b98e33ca491f8d54581971d4d465/view)
 
Record
SN07921233-F 20260813/260811230043 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.