Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF AUGUST 06, 2026 SAM #9019
SOLICITATION NOTICE

Y -- Tionesta Dam Control Tower Concrete Repair

Notice Date
8/4/2026 12:00:00 AM
 
Notice Type
Solicitation
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
W072 ENDIST PITTSBURGH PITTSBURGH PA 15222-4198 USA
 
ZIP Code
15222-4198
 
Solicitation Number
W911WN26QA043
 
Response Due
8/10/2026 2:00:00 PM
 
Archive Date
08/25/2026
 
Point of Contact
Mario TAORMINA, Phone: 4123957256, Connie L. Ferguson, Phone: 4123957551
 
E-Mail Address
Mario.Taormina@usace.army.mil, Connie.L.Ferguson@usace.army.mil
(Mario.Taormina@usace.army.mil, Connie.L.Ferguson@usace.army.mil)
 
Small Business Set-Aside
SBA Small Business Set Aside - Total
 
Description
The U.S. Army Corps of Engineers, Pittsburgh District, requires repairs to a deteriorated section of concrete within the stairwell of the Intake Tower at Tionesta Creek Lake. The repair is necessary to restore watertightness, prevent inundation of interior spaces during high-water events, and maintain safe access for project personnel. The deteriorated section of concrete is located at elevation 1116.5 and encompasses an area approximately 8 feet high from elevation 1116.5, 7 feet wide from the right wall, and at least 8 inches deep, or until the contractor encounters sound concrete. The contractor shall sound the concrete, mark the limits of demolition, and remove all unsound material. After demolition, a non-shrink, low-pressure injection grout shall be installed around the full perimeter of the existing concrete to reduce seepage from the gatewell into the stairwell. Reinforcement shall be installed, which includes horizontal, vertical, and bent-hook bars that are doweled and epoxied into the existing structure. All reinforcement must maintain a minimum clear cover of three inches. A concrete bonding agent shall be applied to all existing surfaces. A hydrophilic waterstop shall be installed along all vertical and horizontal joints to minimize future leakage. Formwork shall be set flush with the existing wall face, and new concrete shall be placed and vibrated to ensure full consolidation and a uniform finish. The North American Industrial Classification Code (NAICS) is 237990 ? Other Heavy and Civil Engineering Construction. The Small Business Size Standard is $45,000,000.00. This procurement is a 100% Small Business Set-Aside. All interested and capable offerors are encouraged to submit a quote. Information regarding the U.S. Army Corps of Engineers process for settling requests for equitable adjustments and duration goals to achieve definitization of equitable adjustments for change orders under construction contracts can be found by going to https://www.usace.army.mil/Strategic-Partnerships/Partnering/mod/129895/details/443/ then scrolling down on right hand side of page by clicking on ?View FFP Contract Changes Playbook Here?. Amendment 0001 is to update the Wage Determination from PA20260002 05/18/2026 to PA20260002 07/30/2026.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/6b3c7bb0281b4d6eb7b39aadad521b8c/view)
 
Place of Performance
Address: 477 Spillway Road, Tionesta, Pennsylvania 16353
Zip Code: 16353
 
Record
SN07911111-F 20260806/260810081817 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.