Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF AUGUST 01, 2026 SAM #9014
SOLICITATION NOTICE

66 -- 66--QUANTSTUDIO 5 384 QPCR SYSTEM

Notice Date
7/30/2026 12:00:00 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
OFFICE OF ACQUISITON GRANTS SACRAMENTO CA 95819 USA
 
ZIP Code
95819
 
Solicitation Number
140G0326Q0060
 
Response Due
8/4/2026 10:00:00 AM
 
Archive Date
08/19/2026
 
Point of Contact
Adam, Elizabeth, Phone: (916) 278-9441, Fax: (916) 278-9339
 
E-Mail Address
eadam@usgs.gov
(eadam@usgs.gov)
 
Description
***AMENDMENT ONE*** The purpose of this Amendment is to answer vendor questions. No further questions will be accepted. QUOTES Quotes must be submitted FOB Destination shipping to Boise, ID, 83702. Quotes are due Tuesday, August 4, 2026, at 10:00am PD. Quotes evaluated by Lowest Price Technically Acceptable (LPTA) Please include lead time in your quote. Quotes accepted by email to the Contracting Officer, Elizabeth Adam, at elizabeth_adam@ios.doi.gov only. QUESTIONS and ANSWERS 1. The salient characteristics require an average sample ramp rate of 3.66�C/sec or greater. Thermo Fisher's published specification for the QuantStudio 5 384-well system states an average sample ramp rate of 2.92�C/sec. Since this is a brand-name-only procurement, please confirm whether 2.92�C/sec is acceptable or whether the requirement will be corrected? This is acceptable. 2. The brand-name justification refers to independently programmed temperature zones across the heat block. Thermo Fisher's published literature indicates that VeriFlex temperature zones are not applicable to the 384-well QuantStudio 5 configuration. Please confirm whether independently programmable temperature zones are a mandatory requirement? This is not required. 3. Please confirm the required Thermo Fisher catalog number and whether the requested configuration must include a laptop or desktop computer? This should not include a computer. Catalog number: A28140 4. Are installation, calibration, onsite setup or user training required? No 5. Is the manufacturer's standard warranty acceptable, and is any extended service coverage required? Standard warranty is acceptable 6. Must the successful contractor be an authorized Thermo Fisher reseller, and should evidence of authorization be included with the quotation? Yes 7. Please confirm whether a manufacturer-issued VPAT/Accessibility Conformance Report and supporting accessibility narrative will satisfy the Section 508 submission requirements. Yes *********************************************** Offerors are to include a technical description of the items being offered in sufficient detail to evaluate compliance with the requirements in the solicitation as seen in the Salient Characteristics (see Attachment). This may include product literature or other documents, if necessary, and is to include the country of manufacture. Offerors shall return the following: Signed SF-18 Signed Amendment Firm, fixed price quote Product information System for Award Management (SAM) Unique Identification Entity (UEI)
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/ba7b50f278ae40febcee7c855cf87010/view)
 
Record
SN07906731-F 20260801/260810080830 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.