Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF JULY 22, 2026 SAM #9004
SOURCES SOUGHT

66 -- Single-Axis Linear Motion Calibration System (Shake Table) with Control Software

Notice Date
7/20/2026 11:55:53 AM
 
Notice Type
Sources Sought
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
FDA OFFICE OF ACQ GRANT SVCS Rockville MD 20852 USA
 
ZIP Code
20852
 
Solicitation Number
SSN-CDRH-2026-133952
 
Response Due
8/3/2026 9:00:00 AM
 
Archive Date
08/04/2026
 
Point of Contact
Reagan Davis, Phone: 3017960910
 
E-Mail Address
reagan.davis@fda.hhs.gov
(reagan.davis@fda.hhs.gov)
 
Small Business Set-Aside
NONE No Set aside used
 
Description
The U.S. Food and Drug Administration requires one (1) complete, turnkey single-axis (one degree-of-freedom) linear motion calibration system, commonly described as a shake table, with control software, for laboratory calibration, verification, and validation testing of inertial measurement devices. The system shall be fully assembled, factory-tested, and factory-calibrated prior to shipment, requiring only unpacking, cable connection, and software installation by the end user. The Government seeks sources able to provide a system meeting, at minimum, the following salient performance characteristics. These are stated in approximate terms for market research; the full minimum specification will accompany any resulting solicitation. � Programmable single-axis linear motion under closed-loop position control with real-time feedback, capable of arbitrary user-defined waveforms including multi-frequency superposition of at least three simultaneous components. Pre-programmed, fixed-routine-only calibrators are not sought. � A motion envelope on the order of 0.1 to 10 Hz in frequency, sub-millimeter to approximately twenty millimeters in displacement, and up to approximately one g in acceleration, with demonstrated small-amplitude positioning accuracy at the sub-millimeter level. � An integrated position sensor and an integrated reference accelerometer, each factory calibrated with NIST-traceable certificates. � Safety features including a hard-wired emergency stop, motion limits, over-current protection, and fault detection with automatic safe shutdown. � Benchtop form factor suitable for standard laboratory power (110 to 120V, or universal input) without special power conditioning or floor reinforcement. � Control software operable in a standalone configuration with no required internet, cloud, or subscription, a programmable interface compatible with MATLAB, Python, or an equivalent industry-standard environment, and non-proprietary data import and export. � Software and electronic content conforming to Section 508 accessibility standards, supported by a Voluntary Product Accessibility Template or equivalent. Estimated quantity: one (1) each. Anticipated delivery: within approximately 90 days after award. Place of delivery: FDA White Oak campus, Silver Spring, Maryland. Applicable standards: NIST-traceable calibration; Section 508. Installation, user training, technical documentation, and a commercial warranty are included in the anticipated requirement.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/c132e199aa064983925081b8ac5b2a97/view)
 
Place of Performance
Address: Silver Spring, MD 20993, USA
Zip Code: 20993
Country: USA
 
Record
SN07892487-F 20260722/260720230052 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.