SOURCES SOUGHT
66 -- Single-Axis Linear Motion Calibration System (Shake Table) with Control Software
- Notice Date
- 7/20/2026 11:55:53 AM
- Notice Type
- Sources Sought
- NAICS
- 334519
— Other Measuring and Controlling Device Manufacturing
- Contracting Office
- FDA OFFICE OF ACQ GRANT SVCS Rockville MD 20852 USA
- ZIP Code
- 20852
- Solicitation Number
- SSN-CDRH-2026-133952
- Response Due
- 8/3/2026 9:00:00 AM
- Archive Date
- 08/04/2026
- Point of Contact
- Reagan Davis, Phone: 3017960910
- E-Mail Address
-
reagan.davis@fda.hhs.gov
(reagan.davis@fda.hhs.gov)
- Small Business Set-Aside
- NONE No Set aside used
- Description
- The U.S. Food and Drug Administration requires one (1) complete, turnkey single-axis (one degree-of-freedom) linear motion calibration system, commonly described as a shake table, with control software, for laboratory calibration, verification, and validation testing of inertial measurement devices. The system shall be fully assembled, factory-tested, and factory-calibrated prior to shipment, requiring only unpacking, cable connection, and software installation by the end user. The Government seeks sources able to provide a system meeting, at minimum, the following salient performance characteristics. These are stated in approximate terms for market research; the full minimum specification will accompany any resulting solicitation. � Programmable single-axis linear motion under closed-loop position control with real-time feedback, capable of arbitrary user-defined waveforms including multi-frequency superposition of at least three simultaneous components. Pre-programmed, fixed-routine-only calibrators are not sought. � A motion envelope on the order of 0.1 to 10 Hz in frequency, sub-millimeter to approximately twenty millimeters in displacement, and up to approximately one g in acceleration, with demonstrated small-amplitude positioning accuracy at the sub-millimeter level. � An integrated position sensor and an integrated reference accelerometer, each factory calibrated with NIST-traceable certificates. � Safety features including a hard-wired emergency stop, motion limits, over-current protection, and fault detection with automatic safe shutdown. � Benchtop form factor suitable for standard laboratory power (110 to 120V, or universal input) without special power conditioning or floor reinforcement. � Control software operable in a standalone configuration with no required internet, cloud, or subscription, a programmable interface compatible with MATLAB, Python, or an equivalent industry-standard environment, and non-proprietary data import and export. � Software and electronic content conforming to Section 508 accessibility standards, supported by a Voluntary Product Accessibility Template or equivalent. Estimated quantity: one (1) each. Anticipated delivery: within approximately 90 days after award. Place of delivery: FDA White Oak campus, Silver Spring, Maryland. Applicable standards: NIST-traceable calibration; Section 508. Installation, user training, technical documentation, and a commercial warranty are included in the anticipated requirement.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/c132e199aa064983925081b8ac5b2a97/view)
- Place of Performance
- Address: Silver Spring, MD 20993, USA
- Zip Code: 20993
- Country: USA
- Zip Code: 20993
- Record
- SN07892487-F 20260722/260720230052 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |