Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF JULY 15, 2026 SAM #8997
SOLICITATION NOTICE

20 -- USCGC POLAR STAR MAIN PROPULSION GENERATOR EXHAUST SYSTEM

Notice Date
7/13/2026 10:34:52 AM
 
Notice Type
Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
 
ZIP Code
94501
 
Solicitation Number
70Z08526Q026573
 
Response Due
7/17/2026 5:00:00 AM
 
Archive Date
08/01/2026
 
Point of Contact
DONNA O'NEAL, Phone: 5103931145, ULISES BALMACEDA, Phone: 2068200307
 
E-Mail Address
Donna.J.O'Neal@uscg.mil, Ulises.O.Balmaceda@uscg.mil
(Donna.J.O'Neal@uscg.mil, Ulises.O.Balmaceda@uscg.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Statement of Work (SOW) -Fabrication and delivery of Exhaust Expansion Joints 1.0 Purpose The purpose of this requirement is to procure the replacement exhaust expansion joint assemblies for the USCGC POLAR STAR Main Propulsion Generator exhaust system. This requirement is for fabrication and shipping only. 2.0 Scope The contractor must furnish all labor, supervision, materials, equipment, tools, and incidentals necessary to fabricate and test the expansion joint assemblies identified in this SOW and in the referenced materials. 3.0 Required Quantities The contractor must fabricate, test and deliver the following: Quantity 2 - 22-inch expansion joints Applicable Documents CG Drawing - 22-inch Expansion Joint Drawing STM F1120 (latest) � Standard Specification for Circular metallic Bellows Type Expansion Joints for Piping Applications Standards of the Expansion Joint Manufacturers Association 5.0 Operating Conditions Normal Operating Temp: 900� F System Design Temp: 1200� F 6.0 General Requirements The Contractor must fabricate the required flex assemblies in strict accordance with the applicable Government-furnished drawings and standards referenced. Any deviation must get written Government approval. The Contractor must provide new materials only. The Contractor must fabricate the assemblies in accordance with applicable Expansion Joint Manufacturers Association standards. The Contractors� quality control must conform to ASTM F1120. Bellows pressure welds shall undergo Liquid Penetrant (PT) Examination. Per the manufacturer's option allowed in ASTM F1120, a Pneumatic Leak Test may be substituted in lieu of the hydrostatic test to protect the dry internal insulation pack. The Contractor must install a permanent metallic data plate, and a permanent directional flow arrow must be visible on the outside of the expansion joint per ASTM F1120 requirements. The Contractor must install shipping bars to lock the assembly rigidly at the 20"" face-to-face dimension during transport. Bars shall be painted a highly visible color (e.g., safety yellow) and clearly marked for their removal after installation is complete. 7.0 Technical Requirements for 22-Inch Expansion Joint For the two 22-inch assemblies, the contractor must fabricate the assemblies in accordance with the referenced drawing package and referenced standards. 8.0 Packaging and Preservation The contractor shall package each fabricated assembly to prevent damage, distortion, contamination, and corrosion during handling and shipment per ASTM F1120. 9.0 Deliverables The contractor shall deliver the following: Quantity 2 of 22-inch multi-ply flex assemblies with liner Certificate of Conformance for each item 10.0 Delivery Required delivery date: 31JUL26 Delivery address: USCGC Polar Star 1519 Alaskan Way S Seattle, WA 98134 Attention: LCDR Joshua Herring Phone: 206-758-7682 11.0 Clarifications If there is any discrepancy between this Statement of Work and the applicable drawing package, the contractor shall notify the Government and obtain clarification before proceeding.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/adfd0884c8724cbc8edc5d126c6a93c2/view)
 
Place of Performance
Address: Seattle, WA 98134, USA
Zip Code: 98134
Country: USA
 
Record
SN07883371-F 20260715/260713230041 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

| FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.