Loren Data's SAM Daily™

fbodaily.com
SAMDAILY.US - ISSUE OF JUNE 13, 2026 SAM #8965
SOLICITATION NOTICE

66 -- Nitrogen and Dry-Air Generator for LC-MS Applications

Notice Date
6/11/2026 4:09:17 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
NAVAL MEDICAL RESEARCH CENTER SILVER SPRING MD 20910-7500 USA
 
ZIP Code
20910-7500
 
Solicitation Number
N3239826Q8561
 
Response Due
6/19/2026 8:59:00 PM
 
Archive Date
07/04/2026
 
Point of Contact
Nataki JOHNSON, MICHAEL PONCZEK
 
E-Mail Address
nataki.s.johnson.civ@health.mil, michael.ponczek@us.af.mil
(nataki.s.johnson.civ@health.mil, michael.ponczek@us.af.mil)
 
Small Business Set-Aside
NONE No Set aside used
 
Description
The Naval Medical Research Command (NMRC) intends to award a contract resulting from this notice to the responsible offeror. All offers must have a Cage Code and a Unique Entity Identification Number.This is being issued on an unrestricted basis to allow for vendors to provide a quote on Equipment Listed in the attached Solicitation (RFQ). The associated NAICS code is 334516. Offerors must also be registered in Systems for Award Management (SAM) at www.sam.gov per FAR 52.212.1 lack of registration in SAM will qualify contractor as ineligible for award. All responsible sources may submit a quotation in response to this notice which shall be considered. The solicitation is being issued as a Request for Quote (RFQ) for a firm fixed type of contract based on the Lowest Price Technically Acceptable. a. The Naval Medical Research Unit Dayton (NAMRU-Dayton) has a requirement for the procurement of one (1) LNI Swissgas NGA CASTORE XL 40.40 Membrane Nitrogen Generator (Part Number: 6920.70.41) to support analytical testing operations in the laboratory. This equipment provides a continuous, high-purity nitrogen gas stream, which is critical for the operation of laboratory analytical instruments, specifically Liquid Chromatography-Mass Spectrometry (LC-MS) systems. b. This generator utilizes specialized membrane technology to separate nitrogen from compressed air. It must deliver a flow rate and purity profile that match the exact requirements of the command's existing mass spectrometers. Deviation from these parameters can cause signal instability, degrade detection limits, void instrument warranties, and lead to costly downtime. **SALIENT CHARACTERISTICS** Nitrogen and dry-air generator for LC-MS applications, LNI Swissgas NGA CASTORE XL iQ 40.40 or equal. Offered system shall be a single, self-contained laboratory gas generator with integrated oil-less compressor and shall not require facility compressed air for normal operation. The system shall provide simultaneous nitrogen and dry-air outputs meeting the following minimum requirements: 1. Nitrogen output: minimum 40 L/min, LCMS-grade nitrogen, purity up to 99.9% or documented equivalent suitable for LC-MS operation. 2. Nitrogen outlet pressure: minimum 8 bar / 116 psi for 220�240 VAC configuration, or minimum 7.5 bar / 108 psi if universal 115�240 VAC configuration is required. 3. Dry-air output: minimum 40 L/min. 4. Dry-air outlet pressure: minimum 8 bar / 116 psi for 220�240 VAC configuration, or minimum 7.5 bar / 108 psi if universal 115�240 VAC configuration is required. 5. Dry-air dew point: ? -40�C atmospheric dew point. 6. Operating noise: ?50 dB(A). 7. Unit footprint: not greater than approximately 59 cm W � 92 cm D � 73 cm H. 8. Controls and monitoring: local touchscreen or equivalent user interface showing system status, pressure/status diagnostics, alarms or pre-alarms; remote start/stop or status monitoring capability via RS485, RS232, digital I/O, Ethernet, or equivalent. 9. Electrical: maximum power draw not to exceed 2.0 kW for 220�240 VAC or 1.7 kW for 115�240 VAC full-range configuration. 10. Integrated or directly compatible UHP nitrogen output capable of at least 200 cc/min at ?99.9999% nitrogen purity, without reducing the main nitrogen/dry-air outputs below required values. 11. Integrated scroll compressor with variable speed technology to preserve power consumption and reduce wear on the compressor system which extends the maintenance interval on the compressor. **WARRANTY** LIMITED WARRANTY - GAS GENERATION SYSTEMS; CALIBRATORS, MIXERS AND SENSORS APPLICABILITY � This warranty is applicable to the forty-eight contiguous United States and Canada only. LNI SWISSGAS US LLC (LNI) warrants that the ITEMS LISTED BELOW shall be free from defects in material and workmanship for the period of time stated below. GAS GENERATION SYSTEMS: Fifteen (15) months from shipment
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/f1f4e4fdc8e24cf1b2c4a8f639a92d48/view)
 
Place of Performance
Address: Wright Patterson AFB, OH 45433, USA
Zip Code: 45433
Country: USA
 
Record
SN07849778-F 20260613/260611230051 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.