J -- 575 Fire System Inspection & Repairs - one year only

Notice Date
6/10/2026 7:29:37 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
561621 — Security Systems Services (except Locksmiths)
 
Contracting Office
NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
 
ZIP Code
80111
 
Solicitation Number
36C25926Q0519
 
Response Due
6/22/2026 4:00:00 PM
 
Archive Date
07/22/2026
 
Point of Contact
Heather Chase, Contracting Officer, Phone: 303-712-5772
 
E-Mail Address
heather.chase2@va.gov
(heather.chase2@va.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
The purpose of this amendment is to: Provide questions, answers and reports provided under previous solicitation (36C25926Q0408). All offers are to be emailed to heather.chase2@va.gov and received no later than 5:00pm MT on June 22, 2026. Questions and Answers below were provided under previous RFQ 36C25926Q0408: Q. Is this a new or follow-on requirement?� If a follow-on, who is the incumbent and what is� the contract number? A. This is a new one-year only requirement. This requirement has not previously been awarded and therefore there is no incumbent. Q. Is the intent of the contract to perform annual testing, identify, and correct deficiencies? A. No, the intent is to correct the deficiencies that have previously been identified and to document the repairs for the Joint Commission audit. Q. Who is currently performing the monitoring service for the VA WCHCS? A. Vulcan Fire. Q. Who is currently performing the backflow preventor service for VA WCHCS? A. Citrine, LLC Q. Can we be provided a copy of the reports? The in-person tags refer to this report. A. Yes. See attached reports.� Q. Does the VA WCHCS have any antifreeze or glycol loops within their fire suppression system? A. Yes, those are located in Building 6 and Building 36. Q. Does the parking garage (Building 44) contain sprinkler systems? A. No, but there are alarm systems. Q. Building 34 has an open deficiency tag for network issues. Has this been resolved? A. This deficiency correction is currently in progress. Q. For the 5-year internal inspections, is it just the internal piping 5-year you are needing? A. Yes, it is the internal piping to include the removal of a flushing connections and sprinkler near the end of a branch line. Will also require photographic evidence of the state of the pipe to fulfill the 5-year requirement. Q. For the OS&Y valves, would you know what size the valves are? A. OS&Y valves on station are 8inch, 3inch, 2.5inch and 6 inch. Q. Do you know what size the inspectors test valves are? A. There are currently no sizing listed in the report. It will be the Contractors responsibility to verify prior to beginning work. Q. Do you know what size the flow switch is in building 22? A. There is currently no size listed in the report. It will be the Contractors responsibility to verify prior to beginning work.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/2870245061bd451686203ddd4620e71a/view)
 
Place of Performance
Address: Department of Veterans Affairs VA Western Colorado Healthcare System 2121 North Ave., Grand Junction 81501
Zip Code: 81501
 
Record
SN07846943-F 20260612/260610230125 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.