Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 06, 2026 SAM #8958
SOURCES SOUGHT

J -- Sources Sought for Repair Fire Alarms Multi Facilities, JBPHH-HI

Notice Date
6/4/2026 6:38:25 PM
 
Notice Type
Sources Sought
 
NAICS
561621 — Security Systems Services (except Locksmiths)
 
Contracting Office
W7M4 USPFO ACTIVITY HIANG 154 KAPOLEI HI 96707-0000 USA
 
ZIP Code
96707-0000
 
Solicitation Number
W50SLF26X1BW2
 
Response Due
6/18/2026 7:00:00 PM
 
Archive Date
07/03/2026
 
Point of Contact
Emma Newbegin, Cezar Y. de Veas
 
E-Mail Address
emma.a.newbegin.civ@army.mil, cezar.y.deveas.mil@army.mil
(emma.a.newbegin.civ@army.mil, cezar.y.deveas.mil@army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This announcement is a Sources Sought (Market Research) Notice. This is not a Request for Quote (RFQ) or Request for Proposal (RFP). The Government is seeking to identify qualified and responsible sources who are capable of performing the services described herein. The purpose of this notice is to gain knowledge of potential qualified sources and their capabilities. Responses due no later than 4:00PM HST, Thursday, 18 JUNE 2026. Send responses to Emma Newbegin at emma.a.newbegin.civ@army.mil The Hawaii Air National Guard (HIANG) requires comprehensive assessment, repair, and inspection of fire alarm and suppression systems for multiple facilities at Joint Base Pearl Harbor-Hickam (JBPHH), HI. Several buildings have failed previous annual inspections and have known deficiencies that must be rectified before a re-inspection can be successfully completed. All work must be performed in accordance with applicable federal, state, and local fire codes and regulations, including UFC 3-601-02. Scope of Work The contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary to perform a comprehensive assessment, execute required repairs, and conduct post-repair operational testing and annual inspections for the fire alarm and life safety systems in the following buildings: 3376, 3382 (Main & Annex), 3380, 3379, 3392, and 3417. The scope of work includes, but is not limited to, the following major tasks: Fire Alarm Control Panel (FACP): Address ""trouble"" and ""disable"" statuses, and replace, program, and test FACPs in multiple buildings. Transmitter & Antenna: Resolve communication issues and replace, program, and test transmitters and antennas. System Components: Replace and test various system batteries, heat detectors, wiring, and sensors as required per building. Fire Suppression System: Address and repair drain failures on a fire suppression riser. Special Systems: Program and test a new walk-in refrigerator alarm system. Inspection and Reporting: Upon completion of repairs, conduct a full annual inspection in accordance with NFPA 72 standards and submit detailed reports, including a completed NFPA 72 ""Fire Alarm and Emergency Communication System Inspection and Testing Form"" for each building. Documentation: Provide pre-work submittals (e.g., material lists, safety plans, personnel qualifications) and post-work closeout documents (e.g., O&M manuals, warranty information, as-built drawings). The work will be performed at the Hawaii Air National Guard Campus, Joint Base Pearl Harbor-Hickam (JBPHH), HI 96853. Period of Performance The estimated period of performance is 180 days, tentatively scheduled from September 1, 2026, to February 27, 2027. Required Capabilities Interested parties must demonstrate experience in the assessment, repair, and certification of complex fire alarm and suppression systems. All personnel performing technical work must meet the State of Hawaii's minimum licensing and certification requirements for Fire Alarm system technicians. A NICET (National Institute for Certification in Engineering Technologies) certification in Fire Alarm Systems is highly desirable. Submission Requirements for Interested Parties Interested parties who believe they have the capability to perform the work described above are invited to submit a capability statement. The statement should include: Company Information: Vendor name, Vendor CAGE, Vendor UEI, point of contact, phone number, and email address. Business Size: Business size and socioeconomic status (e.g., Small Business, 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, etc.). Capability Narrative: A brief narrative detailing your company's experience with projects of a similar scope, size, and complexity. Please provide at least two (2) examples of relevant past projects. Personnel Qualifications: A summary of the qualifications, certifications (e.g., State of Hawaii licenses, NICET), and experience of your key personnel. Teaming Arrangements: Any potential teaming or subcontracting arrangements. Firms responding to this sources sought notice , who fail to provde all of the required information requested, will not be used to assist the Governerment in the acqusiition deicision. Fascimile submissions will not be accepted. NOTE: IF YOU DO NOT INTEND TO SUBMIT A QUOTE FOR THIS REQUIREMENT WHEN IT IS FORMALLY ADVERTISED, PLEASE DO NOT SUBMIT A RESPONSE TO THIS SEEKING SOURCES NOTICE. Responses due no later than 4:00PM HST, Thursday, 18 JUNE 2026. Send responses to Emma Newbegin at emma.a.newbegin.civ@army.mil
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/f86e803d410748a0abf7bd6591f1a43d/view)
 
Place of Performance
Address: JBPHH, HI, USA
Country: USA
 
Record
SN07841471-F 20260606/260604230052 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.