SOLICITATION NOTICE
41 -- HVAC Replacement Parts
- Notice Date
- 5/7/2026 8:37:43 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
- ZIP Code
- 30904
- Solicitation Number
- 36C24726Q0493
- Response Due
- 5/11/2026 9:00:00 AM
- Archive Date
- 05/26/2026
- Point of Contact
- Jessica Cummings, Contract Specialist, Phone: (803) 776-4000 x7801
- E-Mail Address
-
Jessica.Cummings3@va.gov
(Jessica.Cummings3@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business Set Aside
- Awardee
- null
- Description
- Salient Characteristics HVAC Cooling Chassis Units Columbia VA Medical Center 1. Requirement Overview The Government requires the purchase of twenty (20) HVAC cooling chassis units to support existing wall-mounted HVAC systems at the Columbia VA Medical Center. This is a supply-only requirement. Installation will be performed by VA Engineering staff. 2. Brand Name Requirement The Government requires: Islandaire EZ15A7KFA1K14AB Cooling Chassis Units This is a Brand Name Only requirement. No substitutions or equal products will be accepted due to compatibility requirements with existing installed equipment and wall sleeve systems. 3. Minimum Technical Requirements The equipment shall meet the following minimum characteristics: Cooling Capacity: 14,500 BTU � Voltage: 277V � Electrical Requirements: Compatible with existing facility power infrastructure � Heating: No additional electric heat required; unit must be compatible with existing hot water coil heating configuration currently installed at the facility � Configuration: Cooling chassis designed for existing wall sleeve installation � Compatibility: Must fully integrate with existing Islandaire wall sleeve systems currently installed at Columbia VA Medical Center � Infrastructure: Units shall require no modification to existing HVAC infrastructure or wall sleeve assemblies � Construction: Commercial-grade HVAC unit suitable for institutional use � Condition: New equipment only; refurbished or used equipment will not be accepted � 4. Compatibility Requirements The units must: Integrate directly into existing HVAC wall sleeve systems � Maintain compatibility with the existing heating and cooling operational configuration currently utilized by the facility � Maintain operational continuity with existing installed equipment � Require no modification, adapters, redesign, or alterations to existing infrastructure � Products requiring redesign or modification to existing systems will not be accepted. 5. Delivery Requirements Quantity: 20 Each � Delivery Location: Columbia VA Medical Center � Delivery Timeline: 6 8 Weeks After Receipt of Order (ARO) 6. Warranty The contractor shall provide: Standard manufacturer warranty � Warranty documentation at time of delivery 7. Contractor Requirements Offerors shall provide: Exact brand name product specified � Manufacturer specification sheets � Authorized distributor information, if applicable
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/89e0c8679dcb4913a92d752439ce0969/view)
- Place of Performance
- Address: Department of Veteran Affairs WJB Dorn VA Medical Center 6439 Garners Ferry Rd, Building # 105, Columbia, SC 29209, USA
- Zip Code: 29209
- Country: USA
- Zip Code: 29209
- Record
- SN07807374-F 20260509/260507230043 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |