SOLICITATION NOTICE
Z -- Parking Garage (Building 213) Maintenance and Repairs MTH VAMC
- Notice Date
- 4/28/2026 7:31:04 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238990
— All Other Specialty Trade Contractors
- Contracting Office
- 249-NETWORK CONTRACT OFFICE 9 (36C249) MURFREESBORO TN 37129 USA
- ZIP Code
- 37129
- Solicitation Number
- 36C24926Q0173
- Response Due
- 4/30/2026 9:00:00 AM
- Archive Date
- 05/30/2026
- Point of Contact
- diane.ziegler@va.gov, Diane Ziegler, Phone: 615-225-6479
- E-Mail Address
-
diane.ziegler@va.gov
(diane.ziegler@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business Set Aside
- Awardee
- null
- Description
- Q & A RFQ 36C24926Q0173 Q: Inquiring to see if there is going to be a site-walk visit? A: Yes, if requested. Q: We would like to submit questions in relation of the scope. See below: Is power washing required monthly, quarterly, or only as needed? Is re-striping expected annually, as needed, or included in the monthly service price? Should the contractor assume full re-striping each cycle or only touch-up of faded markings? How many weld repairs are anticipated annually? The SOW species Weld Repairs (each) how is a single repair defined (LF, location, or connection)? Will a pre-bid site visit be scheduled to assess current condition of the parking garage? A: Cleaning shall be conducted biannually, specifically post-winter season and pre-winter season. The scheduling will be coordinated with the selected contractor. The request for painting services is for once a year. It is anticipated that the coating will maintain its integrity for a minimum of one year; failure to do so will necessitate the contractor performing all applicable touch-up procedures at no additional cost. The scope of work entails repairing one of the connection joints between the panels, comprising ten pre-installed stainless steel plates arranged at designated intervals along the joint. After welding, the joint must be sealed with an approved silicone sealant to safeguard the plates from environmental damage; the proposed silicone product must be submitted for formal approval prior to application. The scope of work entails repairing one of the connection joints between the panels, comprising ten pre-installed stainless steel plates arranged at designated intervals along the joint. Yes, if requested.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/716ae3de4cb84fd18ff7e322cbd12026/view)
- Record
- SN07794343-F 20260430/260428230039 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |