SPECIAL NOTICE
43 -- Modular Helium Compression System � OEM Equipment Manufacturer Inquiry
- Notice Date
- 1/6/2026 7:30:50 AM
- Notice Type
- Special Notice
- NAICS
- 333914
— Measuring, Dispensing, and Other Pumping Equipment Manufacturing
- Contracting Office
- NASA SHARED SERVICES CENTER STENNIS SPACE CENTER MS 39529 USA
- ZIP Code
- 39529
- Solicitation Number
- 80SSC026K0002
- Response Due
- 1/16/2026 12:00:00 PM
- Archive Date
- 01/31/2026
- Point of Contact
- James Hibbs, Phone: 877-677-2123, Will Garrett
- E-Mail Address
-
james.s.hibbs@nasa.gov, will.c.garrett@nasa.gov
(james.s.hibbs@nasa.gov, will.c.garrett@nasa.gov)
- Small Business Set-Aside
- NONE No Set aside used
- Description
- Request for Information (RFI) Title: Modular Helium Compression System � OEM Equipment Manufacturer Inquiry Location: Building 3305, High Pressure Gas Facility, Stennis Space Center, MS 39529 1. Purpose This Request for Information (RFI) is issued to identify qualified original equipment manufacturers (OEMs) capable of supplying two(2) commercial off-the-shelf (COTS), modular, skid-mounted helium compression system for high-pressure helium applications. The Government is seeking equipment manufacturers only�not general contractors or engineering firms�who can provide the equipment only or a complete turnkey solution including surrounding infrastructure design, fabrication, delivery, installation, and commissioning of the system. The compressed helium will be routed directly into existing on-site infrastructure. The system must be compatible with standard industry transfer connections and designed to integrate seamlessly with existing facility utilities and controls. 2. System Requirements 2.1 Performance Capacity Medium: Helium Inlet Pressure: 50-175 PSIG Final Discharge Pressure: 6000 PSIG Max Capacity: 300 SCFM VFD Driven 2.2 Technology Fully automated operation with remote/local control capabilities MODBUS TCP/IP communication Oil removal filtration system with residual oil content < 0.01 mg/m� 2.3 Design & Footprint Modular, skid-mounted, cabinet-enclosed configuration Exterior operation Sea-level installation Operating within the following temperature ranges: Season Average High Average Low Winter (Dec�Feb) 63�67�F 41�44�F Spring (Mar�May) 73�81�F 50�70�F Summer (Jun�Aug) 90�93�F 71�73�F Fall (Sep�Nov) 72�88�F 47�69�F 2.4 Turnkey Scope OEM must provide (by delivery): Fabrication and factory testing Delivery and installation Commissioning and activation Operator training and documentation 2.5 Operational Features Instrumentation for pressure, temperature, and flow monitoring Emergency stop and alarm systems Oil/water separators, safety valves, and ASME-certified buffer tanks Relocation capability 3. Requested Information � Interested OEMs are requested to submit the following: Company profile, UEI, business size, socio-economic category and relevant experience with helium compression systems Technical specifications of the proposed system Conceptual diagrams Utility requirements (power, cooling water, etc.) Estimated lead time for: Procurement/fabrication Delivery Installation and commissioning Maintenance and support offerings References or case studies of similar systems delivered 4. Manufacturing and U.S. Presence Please include: Country of manufacture for major system components U.S.-based presence (e.g., offices, service teams, fabrication facilities) Availability of U.S.-based technical support and field service personnel 5. Pricing Information Please provide the following pricing details: Budgetary Rough Order of Magnitude (ROM) pricing Tariff-impacted pricing: Include any applicable import duties or tariffs Non-tariff pricing: Provide pricing assuming no tariffs or duties apply Notes on tariff origin: Identify any components or subsystems sourced from countries subject to U.S. import tariffs Additional RFI Information The market research information gathered from this RFI will be used to develop and plan a potential future procurement. Based upon information submitted in response to this RFI, NASA will determine the final content of any future solicitation(s). A determination by the Government not to procure this requirement, based upon responses to this notice, is solely within the discretion of the Government. This notice should not be construed as a formal Request for Quotation (RFQ) or Proposal (RFP). Responses to this RFI are not offers and cannot be accepted by NASA to form a binding contract. This notice is not to be construed as a commitment by the Government to make a purchase, nor will the Government pay for the information solicited or be held liable for any information obtained. Submission of any information in response to this notice is completely voluntary. Comments or suggestions relevant to this requirement are welcome and may also be included in the response. Contractors are welcome to submit any additional documentation that may support their ability to comply with the Government�s requirement. No solicitation exists; therefore, do not request a copy of the solicitation. Here is a complete list of acronyms found across both documents: Acronym Definition AC Alternating Current ASME American Society of Mechanical Engineers ASTM American Society for Testing and Materials CE Conformit� Europ�enne (European Conformity) CSA Canadian Standards Association cULus UL Certification for Canada and the U.S. CFM Cubic Feet per Minute CTick / RCM Regulatory Compliance Mark (Australia/New Zealand) EX-WORKS Ex Works (Incoterms � shipping term) FM Factory Mutual HMI Human-Machine Interface ISO International Organization for Standardization lbs Pounds mg/m� Milligrams per Cubic Meter NEMA National Electrical Manufacturers Association NFPA National Fire Protection Association P&ID Piping and Instrumentation Diagram PLC Programmable Logic Controller PSIG Pounds per Square Inch Gauge rpm Revolutions Per Minute SCFM Standard Cubic Feet per Minute TEFC Totally Enclosed Fan-Cooled TFT Thin-Film Transistor (display technology) UL Underwriters Laboratories VFD Variable Frequency Drive V Volts
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/2d78730126be4890b69dda0c628c76ba/view)
- Place of Performance
- Address: Stennis Space Center, MS 39529, USA
- Zip Code: 39529
- Country: USA
- Zip Code: 39529
- Record
- SN07678152-F 20260108/260106230031 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |