SOLICITATION NOTICE
J -- Garage Door Maintenance and Repair at American Lake VAMC
- Notice Date
- 12/17/2025 9:07:06 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238290
— Other Building Equipment Contractors
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98661 USA
- ZIP Code
- 98661
- Solicitation Number
- 36C26026Q0192
- Response Due
- 1/2/2026 3:00:00 PM
- Archive Date
- 01/17/2026
- Point of Contact
- Adam Hill, Phone: 3605537678
- E-Mail Address
-
Adam.Hill3@va.gov
(Adam.Hill3@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The Department of Veterans Affairs, American Lake VA Medical Center requires Garage Door Maintenance, Repair and Replacement services in accordance with the statement of work. See salient characteristics for brand name or equal to specifications. This is notice of a total SB set-aside. Offerors must be registered as a certified SB in the SBA DSBS database at time of offer and award to be considered eligible. See section E.8 for submission requirements and 52.225 Buy American Certification. Questions for this RFQ will be accepted by email only at adam.hill3@va.gov on or before 12/29/2025. It is highly recommended that all interested Vendors attend a site visit on 12/12/2025 10:00 PST at American Lake VAMC Bldg 18 Lobby. RSVP Adam Hill adam.hill3@va.gov by 12/11/2025. Amendment 0001 On Bldg 21 � We are unable to get a door that is 8x9�2� due to the headroom available. R&S Manufacturing makes their headplates 16� making the door we could get 8x9�8�. This will make it stick in the opening 6�. Eligible offerors and quotes conforming to the submission requirements will be evaluated based on the salient characteristics and technical specifications submitted of all equipment quoted. Please see new attachments; Attachment A � Door Specifications and Attachment B - Door Photos. Building 20 � Three doors have motors with no safety devices. We would need to install new motor with safety devices. Or make the doors manual and install slide locks on the inside. The requirement does not include motor replacement for the doors where maintenance and repairs are being conducted (QTY4EA Doors). The contractor shall perform maintenance and minor repairs only, including rollers, hinges, springs, lubrication, and calibration. Existing VA owned motors are to remain in place and are not to be replaced. The two doors needing replaced have Safe Edges, but the new motors will come with photo-eyes. Do you still want safe edges? The salient characteristics require UL 325 compliant entrapment protection using monitored photo eyes or edge sensors. Any Edge sensors quoted must meet compliance with UL 325. On the new doors, will bake on gray primer be okay. Or do you want powder coated and if so what color? The required finish is baked-on grey polyester primer as stated in the salient characteristics. Powder coating is not required.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/fa9a81a525144b09b42c4ac1dec2536f/view)
- Place of Performance
- Address: WA 98493, USA
- Zip Code: 98493
- Country: USA
- Zip Code: 98493
- Record
- SN07668724-F 20251219/251217230034 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |