Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 02, 2025 SAM #8711
SOLICITATION NOTICE

54 -- Environmental Enclosure Request for Pre-Proposals

Notice Date
9/30/2025 6:47:51 AM
 
Notice Type
Solicitation
 
NAICS
332439 — Other Metal Container Manufacturing
 
Contracting Office
W6QK ACC-APG ABERDEEN PROVING GROU MD 21010-5424 USA
 
ZIP Code
21010-5424
 
Solicitation Number
W911SR-26-R-ENCL
 
Response Due
10/14/2025 2:00:00 PM
 
Archive Date
10/29/2025
 
Point of Contact
Erin Roos - Contract Specialist, Samantha Degele
 
E-Mail Address
erin.c.roos.civ@army.mil, samantha.l.degele.civ@army.mil
(erin.c.roos.civ@army.mil, samantha.l.degele.civ@army.mil)
 
Description
This is a REQUEST FOR PREPROPOSALS (White Paper) UNDER THE ""CWMD BOTAA-24-01."" (Please follow the steps for submission that are attached in the BOTAA.) The Government Intends to Award this Contract as an Other Transaction Authority (OTA). In addition, please refer to the RFI Announcement for Answers to the Questions from the Industry SITE VISIT (W911SR-25-R-ENCL). The U.S. Army Contracting Command � Aberdeen Proving Ground (ACC-APG) is exploring options for a contractor to design and build one enclosure inside of an existing surety chamber for use with highly hazardous materials located at the Aberdeen Proving Ground, Edgewood Area, Maryland. The contractor will be responsible for measuring, designing, fabricating, delivering and installing the enclosure and delivering 100% of the design drawings. The internal surfaces of the enclosure should be stainless steel to be compatible with bleach or caustic solutions. The desired external dimensions of the enclosure are 22 feet long, 10 feet wide, and 9 feet tall, with a minimum 6 foot tall by 4 foot wide door on each of the 22 foot long sides. The enclosure must be able to be assembled in place or assembled remotely and placed into the chamber through a door approximately 13 feet wide and 10 feet tall. The floor of the enclosure must be level, elevated from the existing structure by approximately 6 inches, and must be able to hold the weight of four adults plus ancillary equipment (stationary and moving). The enclosure will be operated with the surrounding chamber maintained at approximately 22 �C and will be required to control and maintain temperature from 0 to 50 �C, the humidity from 5% to 80% relative humidity, and a unidirectional wind speed from 2-12 meters per second across the longest side of the enclosure. The enclosure must be held at a negative pressure differential compared to the surrounding chamber. The enclosure must be able to be viewed remotely, with lighting sources and camera feeds available. The enclosure must contain a space where exterior equipment may pass through (sensor data lines, power cables, etc). All work under this project must be completed in accordance with all applicable U.S laws, regulations, policies, and procedures. POTENTIAL PERIOD OF PERFORMANCE: One year (twelve months) The Government will not reimburse contractors or responders to this notice for any costs incurred in responding, or any subsequent exchange of information. All Pre-Proposals shall be sent electronically to both Agreements Officer, Samantha Degele, at e-mail samantha.l.degele.civ@army.mil and Agreement Specialist, Erin Roos, at e-mail erin.c.roos.civ@army.mil, no later than 5 p.m. EDT on 14 October 2025.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/54aa39ee610e4291932500871ff089e1/view)
 
Place of Performance
Address: Gunpowder, MD, USA
Country: USA
 
Record
SN07608803-F 20251002/250930230040 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.