Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 14, 2025 SAM #8693
SOLICITATION NOTICE

81 -- Robert C. Byrd Locks and Dam Miter Gate Cylinder

Notice Date
9/12/2025 5:26:13 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333995 — Fluid Power Cylinder and Actuator Manufacturing
 
Contracting Office
W072 ENDIST HUNTINGTON HUNTINGTON WV 25701-5000 USA
 
ZIP Code
25701-5000
 
Solicitation Number
W9123725QA063
 
Response Due
9/16/2025 8:00:00 AM
 
Archive Date
09/12/2026
 
Point of Contact
Andrew Barlament, Phone: 4123957478
 
E-Mail Address
andrew.barlament@usace.army.mil
(andrew.barlament@usace.army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Combined Synopsis/Solicitation for Commercial Supplies and ServicesSolicitation Number: W9123725QA063Posting Date: 3 September 2025Federal Acquisition Circular (FAC) Date: 2025-05Product/Service Codes: 8120NAICS Code: 333995Business Size Standard: 800 employeesSet-Aside: 100% Small BusinessGovernment Organization: U.S. Army Corps of Engineers, Huntington DistrictDescription:This is a solicitation for the rebuilding of a Tie Rod Cylinder including disassembly, examination, replacement and fabrication of components, re-assembly, testing, painting, pickup and delivery. The Tie Rod Cylinder is a miter gate operating cylinder used at Robert C. Byrd Locks and Dam (RCB). The cylinder has a 10? inch diameter bore and 5-1/2? inch diameter piston rod with a total stroke of 196 9/16 inches. The Contractor shall fabricate a new piston and other components as shown on RCB As Built DWG. 1480-D. A stem adapter (piston rod end on as-built drawing) is welded to the rod end of the cylinder. The stem adapter will need to be removed and replaced. The threads of the rod will need to be repaired. The new stem adapter will need to have threads match the rod end threads. Contractor to return the new stem adapter threaded onto the rod end with the slot in the new adapter facing up as shown in the attached photographs.The minimum which shall be required shall be the fabrication and replacement of piston, piston seals and wear rings, rod gland with wiper, seal spacer, rod seals, cylinder gasket, and piston rod key, as indicated on As Built. If the chrome is damaged on the piston rod, it shall be removed and re-chromed. The cylinder wall shall be honed to match the rod. Maximum of 0.003? stock removal of tube during cylinder honing. Replacement piston seals and wear rings, rod seals, gaskets, and rod wiper shall be equal to Chesterton products and shall be compatible with the existing grooves and cavities where fitment is required to existing components. The Contractor shall install metal nameplate with the following cylinder information: ?RCB Miter Gate Rehab Date _______. Repaired by: (Name of Machine Shop?. Use month and year in the following format: MM, YYYY. This nameplate shall also have spacer dimensions listed on it. Seals shall be Chesterton products. The rod seals shall be Chesterton Type 11K 800/800 split stacked set V-Ring seals.After disassembly of the cylinder, the Contractor shall furnish the Government a list of any/all additional recommended repairs based on condition of the cylinder components in addition to the repairs outlined in this work scope and the cost thereof prior to commencing with any additional repair. A contract modification will be issued to cover the cost of any additional repairs. The Government reserves the right to inspect the work at any time.Submission Requirements:? Registration in the System for Award Management (SAM) is required: https://www.sam.gov/SAM/? Pricing should be submitted in the format requested by the government.? Offerors are encouraged to add additional relevant products/services.? Submitted prices will remain good for 30 days.Required Delivery/Performance:? Delivery Time (After Receipt of Order): 50 days ARO (After Receipt of Order).? Delivery Locations:1300 Robert C. Byrd RdApple Grove, WV 25502Important Notes:? The Government reserves the right to cancel this combined synopsis/solicitation at any time.? Award will be made to the offerors providing the best value to the Government.? The Contractor is responsible for furnishing all equipment, labor, operators, supervision, quality control, supplies, materials, and incidentals necessary to satisfactorily deliver all supplies.Point of Contact: Andrew Barlament: andrew.s.barlament@usace.army.milMiriaha Sigmon: miriaha.d.sigmon@usace.army.milAdditional Resources:? Procurement Technical Assistance Center (PTAC): http://www.aptac-us.org/contracting-assistance/? System for Award Management (SAM): https://www.sam.gov/SAM/UPDATE 9 September 2025: Amendment 0001 has been published. Please submit a signed copy of the amendment with your quote. The solicitation end date has been extended to 12 September 2025.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/8a655a3220914221b138007fe4c41bae/view)
 
Place of Performance
Address: 1300 Robert C. Byrd RdApple Grove, WV 25502 25502
Zip Code: 25502
 
Record
SN07589513-F 20250914/250912230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.