Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 15, 2025 SAM #8663
SOLICITATION NOTICE

J -- FY25 Replace UPS Control/ COMM Shop

Notice Date
8/13/2025 11:06:04 AM
 
Notice Type
Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
FCI MEMPHIS MEMPHIS TN 38134 USA
 
ZIP Code
38134
 
Solicitation Number
15B11125Q00000022
 
Response Due
8/27/2025 8:00:00 AM
 
Archive Date
09/11/2025
 
Point of Contact
Manuel F. Rosario, Phone: 901-384-5361, Fax: 9013845457, Yourlanda Ghoston-Williams, Phone: 9013725542, Fax: 9013845457
 
E-Mail Address
mfrosario@bop.gov, yghoston-williams@bop.gov
(mfrosario@bop.gov, yghoston-williams@bop.gov)
 
Small Business Set-Aside
NONE No Set aside used
 
Description
The Federal Bureau of Prisons (FBOP), Federal Correctional Institution, Memphis, TN, intends to make an award to single responsible entity for the removal and installation of two (2) Uninterruptible Power Systems capable of providing power for a minimum ninety (90) minute period for the Federal Correctional Institution located at 1101 John A. Denie Road, Memphis, TN. The contractor will provide labor, equipment and materials needed to complete the project. The contractor will complete the following: - Shut off the main power feeds to the existing electrical panels and utilize the Lock out Tag out procedures. - Disconnect the current power feeds from the two (2) old Uninterrupted Power Systems and remove them from service. - Install the 3- position switches on the load side of the UPS systems for ability to swap between the UPS and utility power source. - Install safety disconnects on the line side of the UPS systems to allow for maintenance and or replacement. - The contractor will provide two (2) Uninterrupted Power systems type 9355-30 for the Communication and Control Center. - The contractor will provide Battery cabinets type 9355-30 Part Number: KA1512100000010 for the Communication and Control Center. The battery should provide at least 90 minutes back up power for each UPS system. - The contractor will disconnect current power feeds from the two (2) Uninterrupted Power Systems and re-feed power sources to the existing panels in each area that the UPS provides protection for the Communication Room and Control Center. The Uninterrupted Power Systems specifications Qty (2) 9355-30 Model 20 AC IN: 208 VAC 4 W 50/60 HZ 3P 70 A AC OUT: 208 VAC 4 W 50/60 HZ 3P 55 A 30KW Configuration: KB2013100000110 PLEASE SEE THE ATTACHED SOW FOR FULL DETAILS.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/2b99462ee4ae4c12aef625db3f8d12a8/view)
 
Place of Performance
Address: Memphis, TN 38134, USA
Zip Code: 38134
Country: USA
 
Record
SN07548812-F 20250815/250813230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.