SOURCES SOUGHT
65 -- Tissue Processors with 1-Year Support for the Syracuse VA Medical Center
- Notice Date
- 5/8/2025 12:37:41 PM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
- ZIP Code
- 12208
- Solicitation Number
- 36C24225Q0615
- Response Due
- 5/14/2025 1:00:00 PM
- Archive Date
- 05/29/2025
- Point of Contact
- Myra Florisa N. Green, Contracting Officer, Phone: (518) 626-5450
- E-Mail Address
-
Myra.Green2@va.gov
(Myra.Green2@va.gov)
- Awardee
- null
- Description
- THIS IS A SOURCE SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited. The Government is seeking information for market research purposes only. Your responses to the information requested will assist the Government in determining the appropriate acquisition method. A solicitation is not currently available. The Government may or may not issue solicitation documents. The Department of Veterans Affairs, Veterans Integrated Service Network (VISN 2), is conducting market research for qualified firms, SDVOSB, VOSB or small, that are capable of providing Epredia Revos Tissue Processor with 1-year premium support - brand name or equal to the Syracuse VA Medical Center. Any vendor interested needs to be an authorized reseller, authorized installers and/or manufacturer. The NAICS is 334516 - Analytical Laboratory Instrument Manufacturing is applicable to this acquisition; with a size standard of 1,000 Employees. Statement of Work: Scope of Work The Pathology and Laboratory Medicine Department at the Syracuse VA Medical Center is looking to purchase 2 units of Epredia Revos Tissue Processor with 1-year support - brand name or equal. The 2 instruments will back up one another if the other malfunctions and requires service. B. Procurement Requirements/Specifications/Salient Characteristics: Basis of Design: Tissue Processor: Epredia Revos Tissue Pocessor Part # A84100001ATC Quantity: 2 each 1-Year Premier Support Agreement (Gold) Part # PLA84100001-POS Quantity: 2 each A tissue processor is a device that prepares tissue samples for analysis. It uses different methods to remove water and other substances from the tissue and replace them with a support medium. This allows the tissue to be sectioned and stained without damage or distortion. Tissue processors can also fix, dehydrate, or decalcify the tissue. Common Nomenclature (commercial description): Work-Flow Enhancer Tissue Processor Electrical Data: 100-240 V AC Amperage: 0.6 A +/-10% Frequency: 50/60 Hz Dimensions (D x W x H): 22.83 in x 33.47 in x 53.94 in Weight: Maximum total of 550 pounds Certifications/Compliance: IEC61010 Third Ed. Principles of operation: The instrument s reagent management should track and log reagent usage. It should remember every bottle loaded, protocol executed, and service performed allowing the laboratory to use reagents more efficiently and reduce downtime. Restrictive environmental conditions: N/A Intended use: The Syracuse AP Laboratory requires that 2 tissue processors be purchased, as both of the current tissue processors are deemed beyond economical repair via Syracuse HTM. Equipment with which the item is used: N/A Other pertinent information that describes the item, material or service required: The instrument also should have a filtration system and down-draft ventilation that prohibits unsafe fumes from reaching laboratory staff. Processor must provide a safe environment with a filtration system and down-draft ventilation which helps protect laboratory staff by controlling both solvent and formalin fumes. Processor must have technology that enables the instrument to prevent incorrect replenishment of reagents. Processor must have capability to process/hold at least 250 blocks/cassettes at one time. Processor must have the ability to read barcodes for reagents in order to log the date loaded and lot numbers for quality assurance purposes. Warranty: 1 year manufacturer warranty required 1-year Premium Support must include all replacement parts, labor, and travel expenses for any unscheduled service visit, and a yearly scheduled PM visit. Training: Training and Installation should be included with the purchase C. Place of Performance: Syracuse VA Medical Center Pathology and Laboratory Department 800 Irving Avenue Syracuse, NY 13210 Inspection and acceptance will occur in C318 Delivery as soon as available. . Submission Instructions: All interested parties should respond, in writing via email to Myra.Green2@va.gov referencing 36C24225Q0615 Tissue Processors"" in the subject field. No telephone inquiries will be accepted. In response, please include the following: Business name, address, point of contact, and UEI number. Information describing your interest. Indicate FSS/GSA contract number or Open Market, as applicable. Tax ID number. Company Socio-Economic SIZE (example large, small, SDVOSB, VOSB, WOSB etc.) Capability statement showing authorization to supply A-Dec, Inc. Dental Equipment and Furniture. Evidence of Past Performance or experience in providing the specified product. Confirmation of ability to meet delivery timelines and warranty service. If your firm is a Service-Disabled Veteran Owned or Veteran Owned Small Business, you must be CERTIFIED in SBA Veteran Small Business Certification (VetCert) (see internet site: https://veterans.certify.sba.gov/). Interested firms are reminded that in accordance with FAR 4.1201(a) Prospective contractors shall complete electronic annual representations and certifications at the System for Award Management (SAM) as a part of required registration in conjunction with FAR 4.1102(a) that states, Prospective contractors shall be registered in the (SAM) database prior to award of a contract or agreement. Therefore, due to time constraints, vendors must be registered in System for Award Management (SAM) at http://www.sam.gov to be considered for an award. This notice does not commit the Government to award a contract, nor does it restrict the Government to a particular acquisition approach. Feedback and capability information received may be used to refine the acquisition strategy. Your response is required by 1600 EST on May 14, 2025.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/e79d155c02134cf2b0640f33d6f549a7/view)
- Place of Performance
- Address: Syracuse VA Medical Center Pathology and Laboratory Medicine 800 Irving Avenue, Syracuse 13210
- Zip Code: 13210
- Zip Code: 13210
- Record
- SN07437139-F 20250510/250508230058 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |