SOLICITATION NOTICE
65 -- Integrated Therapy System
- Notice Date
- 4/23/2025 3:11:36 PM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
- ZIP Code
- 85297
- Solicitation Number
- 36C26225Q0833
- Response Due
- 4/29/2025 4:00:00 PM
- Archive Date
- 05/29/2025
- Point of Contact
- Nate Munson, Contract Specialist, Phone: 562-681-2951
- E-Mail Address
-
nathan.munson@va.gov
(nathan.munson@va.gov)
- Awardee
- null
- Description
- This request for information (RFI/Sources Sought) is issued solely for information and planning purposes. This is NOT a solicitation. THERE ARE 19 QUESTIONS AT THE BOTTOM OF THIS DOCUMENT. PLEASE ANSWER THEM COMPLETELY AND THOROUGHLY. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI in accordance with (IAW) Far 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA) is seeking sources capable of providing medical monitors and components. Manufacturer: Bioness Item Description: Integrated Therapy System, Version 2.0, Mobile Configuration, 24 Display with Software Part/Item/Stock #: BIT-2224 Quantity: 1 Must include: Extended Warranty Equal to product Information: Main component: a hardware and software platform using touchscreen technology that allows for patient interaction with different software therapy and assessment programs and mainly intended to challenge and assess vision, motor, cognitive and balance abilities of individuals, directed at those with deficits resulting from traumatic injuries and movement disorders as well as competitive athletes. Salient Characteristics for Integrated Therapy System Must be able to configurate for patients that are confined to bed and accommodate standing activities. Must be mobile with wheels. System must be height adjustable up to but not more than 8 feet tall. Screen must be adjustable to go as tall as 60 inches and as short as 35 inches. Arm of the stand must be adjustable. Display of the system must be an antimicrobial touchscreen at least 24 inches wide. System needs to be hospital grade to meet functional and safety standards. Company must supply a backup battery. Must not be heavier than 20 pounds. The touch buttons on the system must have lights. The list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. If your company is interested and capable of providing the required supplies, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements. For instances where your company cannot meet the salient characteristics requirement(s), please explain. For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR ยง 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to Nate Munson at Nathan.Munson@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, April 29th, 2025 by 4:00 PM EST. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/90557e12c83248048f6099d887f8cf8b/view)
- Place of Performance
- Address: VA Long Beach Healthcare System 5901 East 7th Street, Long Beach 90822-5201, USA
- Zip Code: 90822-5201
- Country: USA
- Zip Code: 90822-5201
- Record
- SN07419205-F 20250425/250423230054 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)