J -- USCGC ALDER GALLEY VENT CLEANING

Notice Date
4/18/2025 10:08:53 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
 
ZIP Code
94501
 
Solicitation Number
70Z085Q0987
 
Response Due
5/2/2025 8:00:00 AM
 
Archive Date
05/02/2025
 
Point of Contact
BRENDEN COX, Phone: 12068315347, Isaiah C. Ragan, Phone: 5104375429
 
E-Mail Address
BRENDEN.S.COX@USCG.MIL, isaiah.c.ragan@uscg.mil
(BRENDEN.S.COX@USCG.MIL, isaiah.c.ragan@uscg.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
SCOPE OF WORK U. S. COAST GUARD CUTTER ALDER ITEM 1: Vent Ducts, Galley and Pantry Room, All, Commercial Cleaning 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to clean and inspect the designated shipboard ventilation systems. 1.2 Government-furnished property. None. 2. REFERENCES Coast Guard Drawings Coast Guard Drawing 225B WLB 512-001, Rev K, HVAC Diagram Coast Guard Drawing 225B WLB 512-007, Rev B, HVAC A&D, Fr 66-92, Innerbttm & 1st Platform Coast Guard Drawing 225 WLB 259-005, Rev C, Combustion Intake & Exhaust A&D Hull Block 940 Coast Guard Publications Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 5100 (SFLC Std Spec 5100), 2022, Clean Shipboard Ventilation Systems Coast Guard Technical Publication (TP) 3796, Section A, Aug 2006, Galley Hood � Model NBDL-60 (13�-4�) Other References None 3. REQUIREMENTS 3.1 General. 3.1.1 CIR. None. 3.1.2 Tech Rep. Not applicable. 3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection). 3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the following: Ducting screens. Electric pre-heaters. Overhead sheathing/panels. Ventilation covers. note Coast Guard personnel will operate all shipboard machinery and equipment. 3.2 Operational test, initial. Prior to commencement of work, the Contractor must witness Coast Guard Personnel perform an initial operational test of the ventilation systems included in this work item, to demonstrate existing operational condition. Submit a CFR. NOTE It is recommended that the Contractor conduct a ship check to verify dimensions in the table below. 3.3 Cleaning requirements. The Contractor must clean and inspect the following ventilation systems, shown on Coast Guard Drawings 225B WLB 512-001, 225B WLB 512-007, and 225 WLB 259-005, in accordance with SFLC Std Spec 5100. Submit a CFR. table � 1 system location SYSTEM LOCATION TYPE Galley Supply 1-57-1-Q (Galley) Exhaust 3.4 Additional requirements. In addition to the above, the Contractor must accomplish the following: 3.4.1 Additional protective covering. In addition to providing protective covering as specified in SFLC Std Spec 5100, subsection 3.1.3 (Protective measures), provide additional protective covering for all food preparation and serving surfaces in the immediate work area, as applicable, to prevent contamination. 3.4.2 Avoidance of meal preparation and service. Ensure that cleaning of galley ventilation systems is scheduled between 1900 and 0530 so that it WILL NOT interfere with meal preparation and service. **If unable to work between 1900 and 0530 ships force will work the KTR work schedule. ** note Coast Guard personnel will operate all shipboard machinery and equipment. 3.5 Operational test, post repairs. After completion of work, the Contractor must thoroughly test, in the presence of the Coast Guard Inspector and demonstrate the ventilation systems included in this work item to be in satisfactory operating condition. Submit a CFR. 4. NOTES CGC ALDER USCGC ALDER (WLB-216) 1 Yerba Buena Island San Francisco, CA 94130 Ph: (415) 399-3590 Chris Laterza, ENG2 Engineer Officer Period of Performance 12 May to 27 May 2025 RDD/POP: 19 July to 31 July 2025
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/5b2ed51f7de94196bcc8161a1cf5fc59/view)
 
Place of Performance
Address: San Francisco, CA 94130, USA
Zip Code: 94130
Country: USA
 
Record
SN07414058-F 20250420/250418230043 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.