SOLICITATION NOTICE
48 -- Repair Fire Suppression
- Notice Date
- 4/13/2025 9:19:36 AM
- Notice Type
- Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- W7N9 USPFO ACTIVITY WYANG 153 CHEYENNE WY 82009-4799 USA
- ZIP Code
- 82009-4799
- Solicitation Number
- W50S8W-25-Q-A004
- Response Due
- 4/25/2025 9:00:00 AM
- Archive Date
- 05/10/2025
- Point of Contact
- Kristopher W Kahle, Phone: 3077726884, Christopher Davalos, Phone: 3077726887
- E-Mail Address
-
kristopher.kahle@us.af.mil, christopher.davalos.1@us.af.mil
(kristopher.kahle@us.af.mil, christopher.davalos.1@us.af.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Fire Pump Inspection and Isolation Contractor shall perform a visual inspection of the fire pump(s), including but not limited to: Pump casing for signs of leaks, cracks, or corrosion Pump shaft and bearings for signs of wear or damage Suction and discharge valves for proper operation Pressure gauges and flow switches for proper function Contractor shall isolate the fire pump(s) from the fire suppression system, ensuring the system remains operational through backup or temporary means during the work. Contractor shall obtain client approval before proceeding with any work. Seal and Solenoid Replacement Contractor shall replace the following components on each fire pump: All mechanical seals All solenoid valves Contractor shall use only new, manufacturer-recommended replacement parts. Contractor shall clean and inspect all mating surfaces before installing new seals and solenoids. Contractor shall follow manufacturer specifications and industry best practices for installation and torquing procedures. Clean Up and Demobilization After replacing the seals and solenoids, the contractor shall reinstate the fire pump(s) into the fire suppression system. Contractor shall perform a comprehensive test of the fire pump(s) and associated systems, including but not limited to: Flow tests to verify pump performance Pressure tests to verify system integrity Alarm and control system functionality Contractor shall record and submit all test results to the client for review and approval. Amendment 1 - Question asked to add photo's of Fire Pump data plate, Mechanical seals and Solenoids. Photo's added as Attachment #1
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/e7e1a294d6af4e4fbbde3130408e7e1f/view)
- Place of Performance
- Address: Cheyenne, WY 82009, USA
- Zip Code: 82009
- Country: USA
- Zip Code: 82009
- Record
- SN07406872-F 20250415/250413230040 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |