Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 19, 2025 SAM #8514
SOURCES SOUGHT

65 -- HEART BYPASS MACHINE - ECMO

Notice Date
3/17/2025 11:08:04 AM
 
Notice Type
Sources Sought
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25525Q0268
 
Response Due
3/31/2025 9:00:00 AM
 
Archive Date
04/10/2025
 
Point of Contact
Betty Flores, Contracting Officer, Phone: 9139461167
 
E-Mail Address
veronica.flores@va.gov
(veronica.flores@va.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following: Heart Bypass Machine for Columbia VAMC *** See Statement of Requirement below for details *** If this is within your capability, please respond with the information below: Company Name Address Point of Contact Phone, Fax, and Email UEI number GSA Contract (as applicable) Capability Statement that clearly and convincingly identifies your ability to fulfill this requirement. Brochures of product being offered to include specifications. Meet the Buy American statute FAR 52.225-1 Authorized distributor letter from OEM Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov Point of Contact for this Sources Sought is: veronica.flores@va.gov Department of Veterans Affairs Network Contracting Office -15 3450 S. 4th Street Trafficway Leavenworth, KS. 66048� STATEMENT OF REQUIREMENTS GENERAL INFORMATION 1.0 Scope of Work: Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Marquet systems are more than 10 years old and need to be replaced. HSTVA is requiring three new heart bypass machines to replace the Marquet system. The components of the heart bypass need to include a Pump, Oxygenator, Heat exchanger, cannulas, and tubing. The system shall be an S5 or newer version of the Heat pump or equal characteristics. 2.0 Background: The current system in place is a Livanova Marquet S1 system. This system is past its end of life and an S5 or newer system or equal needs to be procured. CONTRACTOR REQUIREMENTS 3.0 Technical Requirements/Tasks: The system shall be able to do the following: Shall have a five roller pumps and a monitoring system. The system shall consist of, Roller pumps, double roller pumps, a centrifugal pump, and a system panel. Each roller pump shall have an independent touchscreen control panel that can be adjusted using a knob to set the speed of the electronics in the pump. Shall be able to be rolled around as a cart. Each pump shall be controlled individually:� 1 knob = 1 pump The cockpit and the Patient Monitor shall be connected but operate separately Redundant and individual safety mechanisms Automated sensor checks Integrated warning system based on user-defined thresholds A patient monitor with embedded clinical logic to support data-driven clinical decisions, this monitor shall report all the metabolic information. Shall integrate with HSTVA EMR system, Computerized Patient Record System (CPRS), Veterans Health Information Systems and Technology Architecture (VISTA), and Oracle. Shall have an advanced cable management system and cockpit that provides one central view and control. An ECMO machine primarily consists of� a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes)� that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body;� essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately. The ECMO machine shall include: Pump: This component forcefully pushes the patient's blood through the circuit. Oxygenator (membrane lung): This is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood. Heat exchanger: Ensures the blood is warmed to the patient's body temperature before being returned. Cannulas: Large tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood. Tubing: Connects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit. 5.0 Deliverables / Schedule: Deliverables of this system should be shipped to 800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman, All equipment and components shall be shipped together. All equipment and components shall be tracked upon shipment and tracking number give to the POC. 6.0 Training: Travel for training and install shall be done by vendor after the delivery receipt of the equipment. No additional fees shall be incurred outside the quote. Any fees shall be identified in the quote of the procurement not noted later. The vendor shall handle all traveling to meet the needs of installation and training. Vendor shall provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly. 7.0 Data Rights: All rights and admin privileges shall be handed over to HSTVA upon install of equipment.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/d9ec8757a2f64902ab1cd11b34b7c20c/view)
 
Place of Performance
Address: Department of Veterans Affairs Harry S. Truman Memorial Veterans Hospital 800 Hospital Drive, Columbia 65201-5275, USA
Zip Code: 65201-5275
Country: USA
 
Record
SN07375142-F 20250319/250317230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice