Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 19, 2025 SAM #8514
SOURCES SOUGHT

W -- 6 Month Lease C-Arm XRAY System BRAND NAME OR EQUAL

Notice Date
3/17/2025 11:54:00 AM
 
Notice Type
Sources Sought
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24825Q0546
 
Response Due
3/20/2025 11:00:00 AM
 
Archive Date
04/04/2025
 
Point of Contact
Michael A Shook, Contract Specialist, Phone: 813-972-2000 Ext 2819
 
E-Mail Address
Michael.Shook@va.gov
(Michael.Shook@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Background: The CW Bill Young VA Medical Center has procured a Cath Lab Imaging System to replace the system currently used for Electrophysiology (EP) and Pacemaker procedures. During the construction and replacement of this system, Cardiology Section will be performing these procedures in an Operating Room in the Main OR. The purpose of this contract is to provide the CW Bill Young VA Medical Center (VAMC) with a short-term rental of a Siemens Cios Alpha VA30 System -Portable C-Arm X RAY System NAME BRAND OR EQUAL that will allow the continuation of EP and Pacemaker procedures in the Operating Room during renovation of the EP Cath Lab. Please direct reply in the affirmative via email if you are interested and can provide the required product for this requirement. Please provide capability statement,� I will accept responses for this Sources Sought until the 20th of March 2025 14:00, thanks. 3. Technical Requirements: Unit physical specifications R/F unit, mobile type Full Image type Flat panel detector Minimum detector size [cm] 30 x 30 Minimum central resolution [lp/mm] 2.5 Minimum range of motion orbital rotation [deg] 148 Minimum range of motion pivot rotation [deg] 225 Minimum range of motion panning motion [deg] 12 Minimum range of motion horizontal travel [cm] 20 Minimum range of motion vertical travel [cm] 45 Minimum c-arm depth [in] 28.7 Minimum generator output power [kW] 25 Minimum capacity for images [# of images] 300,000 Minimum image matrix size [pixels] 1952 x 1952 Maximum system dimensions [in] 78 x 33 x 65 Maximum system weight [lbs.] 375 Other physical specifications Additional specifications Flat surface beneath detector to allow for efficient table-top positioning Image magnification with a minimum of 3 settings Consistent field of view during rotation Tube head controls for use by clinician Foot pedal Wireless Centering/alignment light for tube head Reference monitor Motion and metal detection Measurement software Automatic video playback User-configurable threshold dose warning Digital image rotation, reversal, and image invert Selectable mode settings for high-level pulse and low dose Touchscreen monitor UPS on board Automatic brightness stabilization (ABS) control Remote control for entire unit, mountable on the patient table Motorization of orbital, angular, and vertical movement. Advanced applications Digital Subtraction Angiography (DSA) Pulsed cine Bolus chase imaging with single contrast injection Roadmap technology for vascular imaging, to include. Increased frame rate from base model 30fps or greater Real-time digital subtraction Road mapping Increased image storage (1000 images or greater) Bolus tracking Vessel measurement tools and calculations Catheter/guidewire visualization enhancement Preset vascular profiles Security/Connectivity requirements OEM-supported operating system Latest DICOM print, store, commit, structured report (SR) and modality worklist Encrypted hard drive PACS compatibility Philips Intellispace PACS compatibility VA VistA Imaging OR table compatibility Philips NCVA791 Xper Table Tilt Clinical Training On-site clinical applications training for 2 technologists during go-live On-site clinical applications training for 2 physicians during go-live
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/9637d9e4e09f4e9799ab7df0eb9776e6/view)
 
Place of Performance
Address: 10,000 Bay Pines Blvd Bay Pines FL 33744
 
Record
SN07375098-F 20250319/250317230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.