Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 15, 2025 SAM #8510
SOLICITATION NOTICE

66 -- 120-155mm Cannon Laser Bore/ Chamber Add-on Kit to Rigid Delivery Stage Contract W9124R24P0005

Notice Date
3/13/2025 11:51:00 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
W6QM MICC-FT DRUM FORT DRUM NY 13602-5220 USA
 
ZIP Code
13602-5220
 
Solicitation Number
W911S225U0516
 
Response Due
3/19/2025 12:55:00 PM
 
Archive Date
03/13/2026
 
Point of Contact
David Le, Phone: 9283287686, Joy Davis, Phone: 3157729900
 
E-Mail Address
david.v.le.civ@army.mil, joy.l.davis18.civ@army.mil
(david.v.le.civ@army.mil, joy.l.davis18.civ@army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
US Army Yuma Proving Ground shall furnish to contractor following test items for upgrade, system configuration and integration:120mm scanner /sensor hard-sided shipping storage case120mm GTA hard-sided shipping storage case155mm scanner /sensor hard-sided shipping storage case155mm GTA hard-sided shipping storage case The system shall include the following items:One ea. 120mm Cannon Laser Bore Chamber Add-on KitOne ea. 155mm Cannon Laser Bore Chamber Add-on KitThe 120mm Cannon Laser Add-on Bore Gauging Kit shall be operated as a complete turn-key unit and include the following major components:120mm Cannon Bore Chamber Add-on kitGuide tube assembly Certified calibration ring (5 steps)Laser Bore Chamber Calibration Workspace SoftwareThe 155mm Cannon Laser Add-on Bore Gauging Kit shall be operated as a complete turn-key unit and include the following major components:155mm Cannon Bore Chamber Add-on kitGuide tube assembly Certified calibration ring (5 steps)Laser Bore Chamber Calibration Workspace SoftwareThe Laser bore chamber scanning modules shall meet the following specificationsAxial scan resolution: 0.25mm (0.01 inch) minimumRotary scan resolution: 0.1mm (0.004 inch) minimumSensor Resolution: 0.005mm (0.00025 inch)Laser spot size: 0.050mm (0.002 inch) minimumMeasurement repeatability: 0.012mm (0.0005 inch)Measurement Accuracy: minimum of 0.025mm (0.001 inch) in bore and 0.05mm (0.002?) in bore chamberAngular Sampling Resolution: Variable ? up to 0.1 degrees per sample (3,600 samples per revolution)Measuring Range (diameter):Chamber Bore Size Minimum Range Maximum Range120mm 4.7000 in 6.3000 in155mm 6.1950 in 6.8000 inGuide Tube Adapter (GTA)The GTA shall be fitted to muzzle end of 120mm M256 tube model and 155mm XM1299 tube model The GTA shall allow the calibration ring to be removed while the GTA is attached to the cannon muzzle, allowing calibration to be performed with the GTA attached to the cannon muzzleCalibration Ring Set, Guide Tube AdapterEach Calibration Ring shall have five steps (diameters) minimum within the center 75% of the range of the gaugeThe Calibration Rings shall be measured with a NIST-traceable. A2LA Accredited, ISO 17025 and ANS/INCL Z540-1-1994 standardsLaser bore chamber Calibration Workspace SoftwareThe calibration workspace shall meet the requirements outlined in the software sectionSoftwareGeneralData storage shall be compatible with existing YPG Laser bore mapping dataOperating system shall be Windows?-10 based platform System Software License Registration shall be in Soft Key type.Automatic Sensor CalibrationCalibration software shall be capable of conducting an automatic calibration routine Calibration Software shall provide a Pass/Fail display of calibration test resultsf the calibration fails, the software shall automatically calculate corrected calibration parameters Calibration software shall allow the operator to manually adjust offset and slope of the calibration algorithmScanningLaser scan style shall be incremental or helix with the Laser head rotating to collect measurements over 360 degrees at each axial locationAxial and rotary resolution of scans to be user-settable.Data DisplayZoom, pan display functionsProcessed data file and bitmap image exportMultiple, operator-adjustable color palette application to any Color Plot display, with rainbow, thermal grey-scale, and solid color palettesData AnalysisData analysis shall be supported by existing analysis software, with modification if required to meet the requirements in this specificationAnalysis modules for post processing of data including but not limited to calculating: land and groove diameter, area, statistics, reference subtraction, rotate data, remove centering offset, remove undefined data, remove bad data, variable median filter, averaging filterQUALITY ASSURANCE AND WARRANTY PROVISIONSPreservation, packaging and packing shall be in accordance with the manufacturer?s commercial practice.All components shall be covered by a full one-year warranty.Shipping and handling shall be included.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/9170e2ab36fa49a6bcba34ab9550acc5/view)
 
Record
SN07372055-F 20250315/250314000113 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.