Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 15, 2025 SAM #8481
SOURCES SOUGHT

65 -- Guldmann (Or Equivalent) Patient Ceiling Lifts

Notice Date
2/13/2025 8:43:25 AM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25025Q0299
 
Response Due
2/21/2025 2:00:00 PM
 
Archive Date
04/22/2025
 
Point of Contact
Jeffrey Rozema, Contracting Officer, Phone: 269-966-5600 x36450
 
E-Mail Address
jeffrey.rozema@va.gov
(jeffrey.rozema@va.gov)
 
Awardee
null
 
Description
This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the interest and capability of any contractor to meet the requirements listed below, with an emphasis on service-disabled veteran owned small business, veteran owned small business, and other small business. The Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10 is seeking sources for Guldmann (or equivalent) patient ceiling lifts for the Aleda E. Lutz VA Medical Center located at 1500 Weiss Street, Saginaw, MI 48602. The patient ceiling lifts will be installed in the Saginaw VA s Morgue, Nuclear Medicine, Surgery, and Therapy Gyms. The Guldmann lift systems include the following: 4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each Straight Track System GH3+ 605 lbs. SWL. w/Scale includes Hanger Bar, 1 Each 4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each Room Covering System GH3+ 605 lbs. SWL. w/Trainer Module, Positioning Lock System and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each Room Covering System into Straight Rail GH3+ 605 lbs. SWL. w/Trainer Module and and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each 3G Porgram-10 Year Annual Inspection/Preventative Maintenance and Extended Parts and Labor Warranty, 5 Each Design/drafting and installation services are also required. Lift systems must meet the following characteristics/specifications: There must be a lift offered from the manufacturer that can lift at least 600lbs. The transfer gate must be able to support at least 600lbs. The Morgue, Nuclear Medicine, and Surgery rooms must have a X-Y track system (room covering track system) in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back). Therapy Gym Room 1400-22 must have a X-Y track system in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back). The lifts must have a recessed room covering system. The positioning lock system will be needed on the system in Therapy Gym Room 1400-22. A transfer gait will be needed on the system in Therapy Gym Room B600-22 to transfer the Veteran from the room covering system to the straight rail. The track rails must be capable of accommodating stationary lock for lift unit and/or stationary lock for Traverse Rail with user capability via hand control to separately position and lock the motor and/or the traverse rail in designated location(s) when indicated for patient care activity. The hand control must be wired, with LCD screen capable of displaying patient weight and lift usage information for enable staff to easily read the patient s weight. Scale must be internal to maximize hanger bar height and thus lift functionality. Lift must charge anywhere on the track via continuous AC charging. Lifting speed must be minimum 2 inches per second at maximum load capacity, with a soft/slow start and stop. Supplier must be able to provide a lift with automatic, hands free, dynamic body weight support and fall protection in real time during rehab or mobility sessions; clinical staff must be able to enter a specified offload weight directly into the hand control, after which the lift must continually offload the specified weight as patient moves and their center of gravity changes, without the need for staff to continue operating the hand control. Offload weight must be adjustable during a single session so that a patient can progress during that session. The associated North American Industry Classification System (NAICS) Code is 339113 Surgical Appliance and Supplies Manufacturing, and the Business Size Standard is 800 Employees. Contractors that are capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response: (1) Business Name and Address (2) Point of Contact Name, Phone Number and E-mail Address (3) SAM Unique Entity ID (UEI) (4) Type of Small Business (if applicable): Service-Disabled Veteran Owned, Veteran Owned Small Business, 8a, HUBZone, Woman-Owned, etc. (5) Source of supply if you are not the manufacturer (6) Detailed product information/brochures/technical specification/capabilities (7) Product Country of Origin Additional information: All contractors must be registered with the System for Award Management (SAM) at https://sam.gov. Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102. Any contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program (VetCert). Responses due to Jeffrey Rozema, Contract Specialist, by Friday, February 21, 2025, at 5:00 PM Eastern Time. Please e-mail all responses to jeffrey.rozema@va.gov.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/6c7d92cbfc944078adaeee24415c3df3/view)
 
Place of Performance
Address: Department of Veterans Affairs Aleda E. Lutz VA Medical Center 1500 Weiss Street, Saginaw 48602, USA
Zip Code: 48602
Country: USA
 
Record
SN07343114-F 20250215/250213230040 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.