Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 19, 2024 SAM #8423
SOLICITATION NOTICE

61 -- Island Creek Switchyard Transformer

Notice Date
12/17/2024 6:41:25 AM
 
Notice Type
Solicitation
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
W074 ENDIST WILMINGTON WILMINGTON NC 28403-1343 USA
 
ZIP Code
28403-1343
 
Solicitation Number
W912PM-24-R-0005
 
Response Due
1/24/2025 11:00:00 AM
 
Archive Date
02/08/2025
 
Point of Contact
Jenifer Garland, Phone: 9102514314, Troy Small, Phone: 9105244650
 
E-Mail Address
jenifer.m.garland@usace.army.mil, troy.d.small@usace.army.mil
(jenifer.m.garland@usace.army.mil, troy.d.small@usace.army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The U.S. Army Corps of Engineers, Wilmington District requires a contract to provide the design, manufacture, test and deliver two outdoor Class II oil-filled three-phase transformers rated 5,000 kVA high-voltage (H) 4.16 kV low-voltage (x), Class ONAN cooling. A Operations and Maintenance Manual shall be provided for all equipment. Two outdoor 115kV three-pole single -throw, gang � operated, fully automatic circuit switchers, with single pressure interrupter unites using that puffer principle with spring operating amperes continuous current. 25kA symmetrical short circuit amperes. The switchers shall use sulfur hexafluoride (SF6) gas as dielectric and as an are extinguishing medium and be fitted with the manufacturers standard optional grounding switch. The switchers shall include integral motor � operated disconnecting switch blades to open automatically upon overcurrent or fault trip. Include pedestals suitable for mounting the switches on concrete pads. Also, two each outdoor 5kV three � phase, manual � operated, single throw, gang operated metal � enclosed (ME) fusible load break switches, with inspection windows to permit observation of the switch position operation and hinged or removable panels to permit access to that switch for maintenance purposes, without disturbing the bus. The rating shall be 5kV rms maximum voltage, 60kV BIL, 1,200 amperes continuous current, and 40kA symmetrical short circuit amperes. The switch mechanism shall be provided with a lock mechanism or padlock provisions arranged so that the switch can be locked in the open or closed position.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/73fca1551161437d8bd232b40fb2762b/view)
 
Place of Performance
Address: Boydton, VA, USA
Country: USA
 
Record
SN07294985-F 20241219/241217230123 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.