Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 12, 2024 SAM #8416
SOLICITATION NOTICE

41 -- Warehouse Fan Bldg. 10904

Notice Date
12/10/2024 8:15:57 AM
 
Notice Type
Solicitation
 
NAICS
333413 — Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
 
Contracting Office
FA3016 502 CONS CL JBSA LACKLAND TX 78236-5286 USA
 
ZIP Code
78236-5286
 
Solicitation Number
FA301625Q0017
 
Response Due
12/23/2024 10:00:00 AM
 
Archive Date
12/23/2024
 
Point of Contact
Caroline Holmon, Phone: 2106714757, LANCE M WATTERS, Phone: 2105522624
 
E-Mail Address
caroline.holmon.1@us.af.mil, LANCE.WATTERS.1@US.AF.MIL
(caroline.holmon.1@us.af.mil, LANCE.WATTERS.1@US.AF.MIL)
 
Description
Please Review all attachments: Statement of Work(SOW) dated 8 Aug 2024. Salent Characterisitces dated 8 Aug 2024 Solicitation Submit any questions and answers on sheet provided The contractor shall provide all personnel, equipment, supplies, tools, materials, and all non-personal services necessary for purchase and to install one industrial ceiling fan in support of the 344th Training Squadron (TRS), at Lackland bldg. 10904 as defined in this Statement of Work (SOW) Offerors shall inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. SPECIFIC REQUIREMENTS: 1.3.1. The industrial ceiling fan shall be mounted to structural beams and shall have safety cables. 1.3.2. The contractor shall hang the industrial ceiling fan with mount from the manufacturer and installed in accordance with manufacturer specifications. 1.3.3. The contractors shall make electrical connections from the industrial ceiling fan to the power panel. 1.3.4. Structural Grade 8.8 bolts shall be used for mounting. 1.3.5. Wiring shall be in electrical conduit (no exposed wires.) 1.3.6. The contractor shall insure that all possible deflection, vibration, torque, and other such detrimental forces are considered, controlled, and eliminated as necessary. 1.3.7. The contractor shall provide and install all metal conduit, fittings, boxes wire, and switches necessary to establish full and necessary electrical circuits and ensure a perfectly working and code compliant ceiling fan system. 1.3.8. Industrial ceiling fan shall have a minimum drop from support beam of 12�. 1.3.9. Contractor shall install the Fan (bldg. 10904) on main structural ceiling beam 35� 8� from South wall and 75� from the East wall. Fan shall be centered between vertical beams. 1.3.10. Contractor shall install a ceiling fan control box 44� from the east wall next to the current light switch at the south entrance/exit door.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/0366a04e4fb74efbbc15fe19930d1f5b/view)
 
Place of Performance
Address: JBSA Lackland, TX 78236, USA
Zip Code: 78236
Country: USA
 
Record
SN07287306-F 20241212/241210230109 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.