Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 14, 2024 SAM #8327
SOLICITATION NOTICE

12 -- B & F Project 24Z1AIT Building 1 Interior Upgrade Sprinkler System

Notice Date
9/12/2024 1:28:23 PM
 
Notice Type
Solicitation
 
NAICS
333998 —
 
Contracting Office
FCI MEMPHIS MEMPHIS TN 38134 USA
 
ZIP Code
38134
 
Solicitation Number
15B11124Q0000022
 
Response Due
9/17/2024 8:00:00 AM
 
Archive Date
09/17/2024
 
Point of Contact
Yourlanda Ghoston-Williams, Phone: 9013725542, Fax: 9013845457, Latina Barden, Phone: 9013845540, Fax: 9013845457
 
E-Mail Address
yghoston-williams@bop.gov, lbarden@bop.gov
(yghoston-williams@bop.gov, lbarden@bop.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The FCI Memphis is a facility with a rated capacity of 862 low-security inmates within a secure perimeter fence. The Building I was previously utilized in a factory setting when FPI(Federal Prison Industries) used the building. The sprinkler system of Building I will need some upgrades due to the change of use for an inmate programming unit.� The contractor will provide labor, equipment, and materials needed to complete the project at Building I. The work includes, but is not limited to the following:� 1. The contractor will furnish and install a new backflow preventer at the base of the wet pipe system. 2.�The contractor will remove existing pendant fire sprinkler heads and drops throughtout the openceiling with rotating existing pipe upward for new tees and sprinkler heads. 3.��The contractor will disconnect and cap the 2-inch fire sprinkler line through the wall for the adjacent building that is being demolished.� 4.�The classrooms and restrooms will need the fire sprinkler heads replaced and fitted for new grid/sheetrock ceilings. See the attached approved drawings of the layout.� 5. Install new fire sprinkler piping above grid/sheetrock ceilings in restrooms to add fire sprinkler coverage and adjust fire sprinkler heads for proper clearances. 6. Install sway braces, retainer straps, and flexible couplings to protect the system piping from damage due to earthquakes in accordance with NFPA 13.� 7. Test all new fire sprinkler systems in accordance with NFPA 13.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/2795fa9cb3f9499c83dd24004b8b1911/view)
 
Place of Performance
Address: Bartlett, TN 38134, USA
Zip Code: 38134
Country: USA
 
Record
SN07208989-F 20240914/240912230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.