SOLICITATION NOTICE
K -- Raised Floor End of Life Equipment Upgrade
- Notice Date
- 8/30/2024 10:47:15 AM
- Notice Type
- Solicitation
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- IT CONTRACTING DIVISION - PL83 SCOTT AFB IL 62225-5406 USA
- ZIP Code
- 62225-5406
- Solicitation Number
- HC102824R0067
- Response Due
- 9/5/2024 10:00:00 AM
- Archive Date
- 09/20/2024
- Point of Contact
- John M. Ross, Haylee Wheat
- E-Mail Address
-
john.m.ross138.civ@mail.mil, haylee.p.wheat.civ@mail.mil
(john.m.ross138.civ@mail.mil, haylee.p.wheat.civ@mail.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- See attachment,�HC102824R0067 R1 Questions (DISA Response). Additionally,� PDU_2-A-02 is accurately identified on drawing E-107. The drawings I provided in my response reflect the changes to drawings E-604 to indicate accurate replacement. For the CLIN, the total quantity of 125kVA PDUs should be eleven (11). All electrical information on the drawings should now be accurate. -------------------------------------------------------------- RFP AMD01 HC102824R0067 RF EOL extends solicitaion due date�to 5 September 2024. 12:00 PM CST. -------------------------------------------------------------- The existing units (CRAH-66 & 67) are Model # CW114DC1A2A079. Replacement units should match these model types. Brand name or equal replacement. -------------------------------------------------------------- The mechanical sheet M-500 has a typo. It should be CW114 instead CW141. The information noted is accurate and reflects a size available from the Vertiv/Liebert/Emerson website.�� Based on the information for the subject units, model number Liebert CW114DC1A2A079 could be used for this requirement. -------------------------------------------------------------- SPEC, LLC, POC: Greg Howard, 317-903-0241 -------------------------------------------------------------- Added the following attachments: 1.�HC102824R0067 Questions (DISA Response) 2.�Specification - 23 05 53 3.�Specifications - 26 28 01.00 10 4.�Method of Procedure Example 5.�MOP Example The provided design concept does not include drawings E-101, E-103, and E-104. There is no identified work taking place on these drawing sheets. -------------------------------------------------------------- Added attachment, ""Reference Photos"" -------------------------------------------------------------- Added attachment, ""Reference Drawing�E-601 (Additional)"" -------------------------------------------------------------- Added attachments, ""Question and Answers"" and ""26 24 15"". -------------------------------------------------------------- Added attachment, ""Attachment 5 - Site Visit Request Instructions RF EOL"". -------------------------------------------------------------- Data Center Mechanicsburg has Computer Room Air Handlers (CRAH) units and electrical equipment that have reached their end of life and need to be replaced.� All of the equipment serve critical areas and need upgraded to prevent any downtime or mission loss. Provide Data Center Mechanicsburg with new CRAH units, Power Distribution Units (PDU�s), Remote Distribution Cabinets (RDC�s) and any additional electrical as shown on the design concept plans. You must submit a Document Access request. The Access Request Link is located below the Attachments/Links header. You must be logged in and a registered user within your organization. This contracting opportunity is reserved for small businesses registered under NAICS 333415. Document access is unavailable if NAICS 333415 is not part of your organization�s registration.�
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/f0a53342d6cb4da889c71c3898d514e2/view)
- Place of Performance
- Address: Mechanicsburg, PA 17050, USA
- Zip Code: 17050
- Country: USA
- Zip Code: 17050
- Record
- SN07193561-F 20240901/240830230120 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)