Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 08, 2024 SAM #8290
SOURCES SOUGHT

C -- 652-24-101 Improve Electrical Distribution (A/E Contract)

Notice Date
8/6/2024 11:31:01 AM
 
Notice Type
Sources Sought
 
NAICS
541330 — Engineering Services
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24624Q1202
 
Response Due
8/22/2024 1:00:00 PM
 
Archive Date
11/29/2024
 
Point of Contact
Robby Ragos, Contracting Officer
 
E-Mail Address
Robert.Ragos@va.gov
(Robert.Ragos@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
SOURCES SOUGHT: The Richmond, VA VAMC located at 1201 Broad Rock BLVD, Richmond, VA 223249 has a requirement for an A/E Firm Fixed Price contract to design a plan to improve emergency power electrical distribution to operating rooms, ICU headwalls, Emergency Department, and critical patient care area. OVERVIEW The Department of Veterans Affairs, Network Contracting Office 6 is conducting market research to identify potential sources for Architect/Engineer services to complete the below scope of work. The place of performance will be the hospital campus of the Richmond, VA VAMC in Richmond, Virginia. Forward all questions to the point of contact identified below. SCOPE OF WORK The A/E firm shall provide a complete, accurate, and constructable project design that will meet the following objectives: In building 500, conform operating rooms, ICU headwalls, emergency department, and critical patient care areas power distribution with NFPA 99-2024 Chapter 6 and additional applicable NFPA 99-2024 chapters, and NFPA 70-2023 Article 517 code. Install additional power distribution to the affected areas as necessary. The affected areas power shall be fed from at least two independent power sources, a critical branch circuit and normal power branch circuit or a critical branch circuit supplied from a different Automatic Transfer Switch (ATS) from the first critical branch circuit. In the operating rooms and affected areas considered a wet room , power distribution to equipment, receptacles, lighting, etc. shall be from Isolation power panels. Ensure receptacle s quantity and power source in the affected areas are compliant with NFPA 99-2024 6.3.2.2 Review active Richmond VAMC projects that encompass the affected areas. Provide details on the projects that are not in compliance with NFPA 99-2024 and NFPA 70-2023 code. Additional power distribution designed to distribute power from any of building 500 transformer vaults, shall not overload the transformer vaults. Provide requirements and methods in the design to minimize impact to patient care while work is being executed. Electrical outages should be limited to no longer than 8 hours and should be minimized to be as short as possible. NAICS CODE: 541330, Engineering Services (SBA Size Standard: $15 million annual revenue) PRODUCT OR SERVICE CODE (PSC): C1MZ, Architect and Engineering- Construction - Electrical Power Generation (EPG) Facilities - Other. This is not a Request for Proposal: the purpose of this notice is to determine if there are qualified SDVOSB, VOSB and Small Businesses that have the experience for this highly specialized type of work and if such firms are interested in this procurement. In accordance with the magnitude of construction for this project is currently between $2,000,000 and $5,000,000; but is subject to revision prior to release of a solicitation. Interested firms should indicate their interest no later than 1:00 pm EST on 8/22/2024 via email to Contract Specialist Robert.Ragos@va.gov. Veterans Health Administration, Regional Procurement Office East, Network Contracting Office 6. CONTRACTOR RESPONSIBILITY A potential source, for the purposes of this notice, is considered to be any firm meeting any of the following requirements, with experience in managing architect-engineer contracts. Based on responses to this notice, some of the below requirements may be modified, where necessary, prior to release of any solicitation. 1. Requirements for Registration of Architects or Engineers registered to practice in the professional field involved in a State, the District of Columbia, or an outlying area of the United States shall prepare or review and approve the design of architectural, structural, mechanical, electrical, civil, or other engineering features of the work performs work under the applicable NAICS code. 2. The prime source is registered in the System for Award Management (SAM) database at https://www.sam.gov, as whichever entity/office that would receive award in the event of a solicitation. 3. The prime source is registered in the Veteran Small Business Certification (VetCert) database at https://veterans.certify.sba.gov, if applicable. (This is only applicable to firms meeting Small Business Administration (SBA) and VA requirements for Service-Disabled Veteran-Owned Small Business (SDVOSB) or Veteran-Owned Small Business (VOSB) programs.) 4. The prime source has completed submission of the current cycle, for calendar year 2024, VETS-4212 Report at https://www.dol.gov/agencies/vets/programs/vets4212 (for federal contracts in the amount of $150,000.00 or more, performed during the current cycle). 5. The prime source has no more than three serious, or one repeat, or one willful Occupational Safety and Health Administration (OSHA) or Environmental Protection Agency (EPA) violation(s) in the past 3 years and has an Experience Modification Rate (EMR) of equal to or less than 1.0. INSTRUCTIONS FOR RESPONDING: Interested companies can respond, via email, to Robert.ragos@va.gov, with the following information: (1.) Firm Point of Contact, including name, title, phone number and email address. (2.) Firm name, SAM UEI and address of the applicable office. (3.) Summary of architect-engineer contracts previously performed. Failure to submit all information requested will result in a contractor not being considered as an interested SDVOSB, VOSB or SB concern. If adequate interest is not received this action will not be a set-aside. Interested firms should reply via e-mail to Robert.Ragos@va.gov. Visit SAM.gov to register in SAM. SDVOSB or VOSB firms must be certified by the SBA VetCert under the size standard for the NAICS.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/2214379de86c470aa2b4aaa5dba88130/view)
 
Place of Performance
Address: VAMC Richmond Virginia 1201 Broad Rock BLVD Richmond Virginia 23249, USA
Zip Code: 23249
Country: USA
 
Record
SN07159091-F 20240808/240806230127 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.