Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 08, 2024 SAM #8290
SOLICITATION NOTICE

R -- Server Rack Replacement and Cable Management

Notice Date
8/6/2024 3:19:20 PM
 
Notice Type
Solicitation
 
NAICS
541519 — Other Computer Related Services
 
Contracting Office
FA4877 355 CONS PK DAVIS MONTHAN AFB AZ 85707-3522 USA
 
ZIP Code
85707-3522
 
Solicitation Number
FA487724Q0016
 
Response Due
8/14/2024 2:00:00 PM
 
Archive Date
08/29/2024
 
Point of Contact
Cody Daraban, Phone: 5202283704, Joshua Lewis, Phone: 5202284190
 
E-Mail Address
cody.daraban@us.af.mil, joshua.lewis.44@us.af.mil
(cody.daraban@us.af.mil, joshua.lewis.44@us.af.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The 355th Communications Squadron is looking to replace several server racks and have cable management/clean-up services performed in the same racks that are being replaced. The Contractor shall provide all required transportation, personnel, equipment, tools, parts, labor, appropriate supervision, and management needed to accomplish the work requested. A site survey shall be conducted prior to final purchase of necessary equipment to ensure all racks and fiber optic cable for replacement are properly identified and any concerns with facility or overall install are to be addressed. The total count of racks that are to be replaced is 11, 7 in Row #1 Racks 7-14A (rack 11 does not exist) and 4 in Row #2 Racks 1-4: -�� �The replacements must include the following: o�� �42U data center cabinet supporting 19� rack mounted equipment. o�� �Nominal width should be at least 29� with a front opening of at least 25�. o�� �Nominal depth should be at least 39� with rail depth up to 36�. o�� �Must have adjustable rails. o�� �Must have a single perforated front door and a double perforated rear door, both with lockable key latches. o�� �The top panel must have 4 cable openings, one at each corner, with included grommets. o�� �Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel's cable openings but do not interfere with the installation or removal of rack mounted equipment. o�� �Must come with enough cage nuts and screws to populate every slot on all 4 rails. o�� �Must come with a vertical PDU, mounted securely, supporting 48 NEMA 5-20 outlets and a NEMA L6-30 input plug. -�� �Remove equipment from old racks and reinstall in the replacements. -�� �Dispose of the old server racks. The contractor will conduct the following regarding cable management and clean up: -�� �Replace and organize all connections in Row #1 Racks 7-14A (rack 11 doesn't exist) and Row #2 Racks 1-4. -�� �Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability.� -�� �Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: o�� �Pathways o�� �Patch panels o�� �Ports o�� �Cabling o�� �Telecommunications space o�� �Work area outlets o�� �Racks and cabinets o�� �Grounding busbars o�� �Firestop locations o�� �Data center room grid -�� �Update LIU/patch panel labels and legend inserts.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/152d650bc4a3467999f57c0df063d183/view)
 
Place of Performance
Address: Tucson, AZ 85708, USA
Zip Code: 85708
Country: USA
 
Record
SN07158043-F 20240808/240806230119 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.