SOLICITATION NOTICE
65 -- Brand name or Equal Stryker PI Drive 2 Plus
- Notice Date
- 8/5/2024 6:24:18 AM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
- ZIP Code
- 15215
- Solicitation Number
- 36C24424Q0700
- Response Due
- 8/9/2024 1:00:00 PM
- Archive Date
- 08/19/2024
- Point of Contact
- Andrew Taylor, Contracting Officer, Phone: 724-679-2327
- E-Mail Address
-
andrew.taylor3@va.gov
(andrew.taylor3@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Awardee
- null
- Description
- VA Pittsburgh Healthcare System (VAPHS) STATEMENT OF NEED AND GENERAL SPECIFICATIONS Stryker Pi Drive 2+ Motor VA Pittsburgh Healthcare System (VAPHS) STATEMENT OF NEED AND GENERAL SPECIFICATIONS Stryker Pi Drive 2+ Motor Requirement The VA Pittsburgh Healthcare System (VAPHS) is a tertiary referral center for the western half of VA Healthcare VISN 4, treating Veterans from Altoona, Erie, and Butler, in Pennsylvania and Clarksburg, West Virginia. VAPHS proudly serves the Veteran population throughout the tri-state area of Pennsylvania, Ohio, and West Virginia. VAPHS consists of two clinical care facilities in Pittsburgh (HJH and University Drive locations) as well as five community-based outpatient clinics. VAPHS maintains academic affiliations with over 170 associated health educational programs, to include the University of Pittsburgh Schools of Medicine and Dental Medicine. The primary objective of this Statement of Work is to define the scope for the procurement, and integration of the Brand Name or Equal to, Stryker Pi Drive 2+ Motor drill, Model Number 5407-350-000, within our neurosurgery clinic. Our current units in use are obsolete. Its features include the Pi drive design which replaces the nonfunctioning steel core in conventional motors with magnets in a pie configuration. This allows optimization of the space, while reducing overall housing size versus conventional motor designs. Similarly, traditional round wiring looped around the core is exchanged for flat wiring that completely encases it, generating an efficient motor design that can run long and stay cool. These drills are also black anodized which gives less light reflection when utilizing high intensity head lamps. The current drills used in Neurosurgery are of an earlier and now obsolete model. These are an upgraded model of the same product. This will ensure standardization with the other drills in use in the operating room and ensure familiarity with providers working with the drill. Features Motor bearing grease has higher viscosity and max operating temperature (98.6°F increase; 350.6°F vs 284°F) (37ºC increase; 177ºC vs 140ºC) 29% decrease (3.3lbf) in attachment mean peak pullout force Non-footed slam latch and release collar simplify use Matte anodizing and drill coating reduce light reflection/glare off drill surface, reduce corrosion and preserve exterior marking 4+ years (minimum 400 cycles) ~ 50% reduction in sound energy Up to 36% reduction in cable friction (CoF) Drill tracker adapter provides future-ready design Works with I.D. Touch software for custom drill response 75K RPM electric motor Delivery Delivery should be coordinated with the VA Pittsburgh Point of Contact for the contract appointed at award, prior to shipping of any equipment. University Drive VA Pittsburgh Healthcare System University Drive C, Room 2A118 Pittsburgh PA 15240 The Contractor must comply and provide all necessary information to VAPHS. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. Normal business hours for acceptance of deliveries are 8:00am-3:30pm, Monday thru Friday excluding Federal Holidays. Deliveries must be coordinated in advance with the point of contact once a ship date is established. The Biomedical Engineering and/or Logistics Representative shall be the only VA entity signing for freight received on this requirement. The VA-issued purchase order number must be included in the packing slip. All items included in the requirement shall be shipped and delivered to site at same time. If deliveries must be broken into several shipments due to size, this must be coordinated in advance with the VA Point of contact. Failure the coordinate shipment with the point of contact, may result in failure to deliver on site and cause re-scheduling of delivery/freight at no charge to the government. The packing slip must include the VA-issued purchase order number. End of Document
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/9c008abaf3cd49e99310d028de56b61c/view)
- Place of Performance
- Address: VA Pittsburgh Healthcare University Drive C, Pittsburgh 15214, USA
- Zip Code: 15214