Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 30, 2024 SAM #8251
SOLICITATION NOTICE

65 -- Spectrophotometer Surgical Instr.

Notice Date
6/28/2024 11:21:36 AM
 
Notice Type
Presolicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
 
ZIP Code
85297
 
Solicitation Number
36C26224Q1420
 
Response Due
7/5/2024 4:00:00 PM
 
Archive Date
09/03/2024
 
Point of Contact
John harrison, Contract specialist, Phone: 562-766-2267
 
E-Mail Address
john.harrison2@va.gov
(john.harrison2@va.gov)
 
Awardee
null
 
Description
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. ***ALL submissions SHALL Include the following statement: 644 - 36C26224Q1420 Spectrophotometer SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought/RFI/RFI only. The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this Sources Sought/RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought/RFI, a solicitation announcement may be published. Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office, is seeking sources who can possibly provide Spectrophotometer that at a minimum meet the brand name and/or can possibly provide an equal product for Albuquerque, AZ, VA Medical Center Brand name Information: Manufacturer & Part Number: Mettle Toledo - 30254726 Type: Spectrophotometer UV7 Possible Capabilities: Measuring the intensity of light as a beam Equal to product Information: Main component: Spectrophotometer Possible Capabilities: Measuring the intensity of light as a beam The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified in this RFI? (3) Are you the manufacturer, authorized distributor, and/or can you provide equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. (7) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number. (8) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solution you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract. (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items (10) Please indicate whether your product conforms to the requirements of the Buy American Act? (11) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (12) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics or equal to items for planning purposes; show clear, compelling, and convincing evidence that all equal to items"" meet all the salient characteristics. (13) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (14) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to john.harrison@va.gov. Telephone responses will not be accepted. Responses must be received no later than 04/10/2024, by 4:00 PM PST. All responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement. Responses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. Please provide unofficial pricing. Notice: No remanufactures or gray market items/ supplies will not be acceptable. Interested parties of RFI must be an authorized reseller, distributor, or dealer of the O.E.M. (Original Equipment Manufacturer). Verification can be provided by an authorization letter or other documents from the OEM. Equipment shall be in accordance with the OEM terms and conditions. Brand Name items listed solely for Brand name or Equal comparison. ***ALL submissions SHALL Include the following statement: Pre-Solicitation Number: 501 - 36C26224Q1420 Spectrophotometer 30254726 1 Spectrophotometer UV7 1 EA 30750261 2 Base for Autosampler InMotion Flex UVIS 1 EA 30247984 3 Software LabX UV/VIS Express 1 EA 30399071 4 Tubes connecting UV and InMotion 1 EA 30094142 5 Rack InMotion Flex 25ml 1 EA 30750267 6 Flow Cell Kit UV/VIS 25ml 1 EA 30838077 7 Flow Cell quartz 10mm 80ul 1 EA 63057273 8 Desktop/Monitor Data Collection System 1 EA NONE 9 EQPac Comprehensive Qualification UV7 1 EA NONE 10 Service Plan - 2 visit(s) - UV7 1 EA NONE 11 EQPac Comprehensive Qualification Base 1 EA NONE 12 Service Plan - 2 visit(s) - Base 1 EA NONE 13 HANDLING 1 EA TOTAL COST: $ Salient Characteristics - UV Vis Spectrophotometer Spectrometer calibration shall be performed according to European and US pharmacopeia. Shall support 21 CFR Part 11 and data integrity compliance with LabX Software. Instrument must be capable of interfacing with Mettler Toledo lab X software, an Ian system used for all analytical balances, Currently in use at the facility lab. Shall have modern fiber optics combined with a CCD array detector and Xenon flash lamp, allowing for a full spectrum scan within just one second. The optical performance shall fully comply with Pharmacopeia regulations (USP, Ph. Eur.). Instrument shall be operated as a standalone, without the use of a PC. Shall manage sample loads from 11 large beakers (250 mL) up to 50 small glass tubes (25 mL) and combinations in between. Dedicated UV Vis base shall be optimized for the automation of UV visible application Required Specifications Wavelength Range (nm) 190 nm - 1,100 nm Photometric accuracy (K2Cr2O7) ±0.005 A Wavelength accuracy ±0.5 nm Resolution (Toluene in hexane) >1.9 Stray light (KCl, 198nm) >2.3 Compatibility with LabX Software Yes
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/e918d9bce5104e088448d81cb0994312/view)
 
Place of Performance
Address: Department of Veterans Affairs VA Albuquerque Healthcare System 1501 San Pedro Dr SE, Albuquerque, NM 87108
 
Record
SN07112588-F 20240630/240628230125 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.