Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 19, 2024 SAM #8209
SOLICITATION NOTICE

J -- USCGC MUNRO FUEL OIL PIPING

Notice Date
5/17/2024 11:01:23 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
 
ZIP Code
94501
 
Solicitation Number
70Z08524P05011
 
Response Due
5/31/2024 8:00:00 AM
 
Archive Date
05/31/2024
 
Point of Contact
BRENDEN COX, Phone: 12068315347, KYLER FISK, Phone: 9492881271
 
E-Mail Address
BRENDEN.S.COX@USCG.MIL, KYLER.C.FISK@USCG.MIL
(BRENDEN.S.COX@USCG.MIL, KYLER.C.FISK@USCG.MIL)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a total small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. The United States Coast Guard Surface Force Logistics Center has a requirement for the following: The CTR shall provide:� 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to renew piping sections in the fuel oil transfer and fuel oil stripping systems listed in Table 1. 1.2 Government-furnished property. None. 2. REFERENCES COAST GUARD DRAWINGS Coast Guard Drawing 418A-WSML-540-001, Rev C, Fuel Oil Diagram COAST GUARD PUBLICATIONS Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures OTHER REFERENCES None. 3. REQUIREMENTS 3.1 General. 3.1.1 CIR. None. 2 (Rev-0) 3.1.2 Tech Rep. The Contractor must provide the services of qualified and certified Tech Reps and personnel as follows: � NDE Tech Rep: NDE Inspector/Level 2 3.1.2.1 NDE Tech Rep. The Contractor must provide the services of a qualified and certified NDE Inspector as follows: � Perform welding NDE inspections. 3.1.2.1.1 Qualifications/certifications. NDE Inspector/Level 2 certified and qualified in accordance with ASNT No. SNT-TC-1A. Submit the Tech Rep�s qualifications/certifications to the COR at the Arrival Conference. 3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection). 3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the following: � Oil in bilges around fuel manifolds (gas free certification required for hot work) � Deck plating � Miscellaneous piping � Flange spray shields � Fuel transfer manifold � Fuel Oil Tanks (5-76-1-F, 5-76-2-F, 5-80-0-F) 3.2 Operational test, initial. Prior to commencement of work, the Contractor must witness Coast Guard personnel perform an initial operational test of all items or shipboard devices to be disturbed, used, repaired, or altered, to demonstrate existing operational condition. Submit a CFR. 3.3 Fluid handling. The Contractor must remove up to 500 gallons of diesel fuel from the affected piping system and tanks. Stow all fluids in suitable stowage facility immediately after removal, and re-stow all tank contents, upon completion of work. 3.4 Piping isolation. The Contractor must disconnect flange connections and install blanks (with gaskets) as required to isolate the fuel oil transfer piping. The Contractor must isolate and clean the affected fuel oil transfer piping to perform gas freeing and hot work. Remove blanks, reconnect flanges, and renew any disturbed gaskets upon completion piping renewal. Gasket material used in final assembly must conform to those specified in CG Drawing 418A-WSML-540-001. 3.5 Bilge cleaning. The Contractor must clean bilge areas to allow for gas free certification and hot work in the area. 3.6 Fuel oil transfer piping renewal. The Contractor must renew the leaking sections of fuel oil transfer and fuel oil stripping piping described in Table 1. Piping arrangement and material details are provided in Coast Guard Drawing 418A-WMSL-540-001. NOTE Coast Guard personnel will operate all shipboard machinery and equipment. 3 (Rev-0) TABLE 1 � LIST OF F/O PIPING LOCATION / PIPING LINEAR FEET (LF) DIAMETER (in) DRAWING NOTES FMMR (5-44-01-E) F/O Stripping Piping 10 LF 4 in 418A-WMSL-540-001 Sheet 17A Piping section is port side lower level FMMR. FMMR (5-44-01-E) F/O Transfer Piping to 5-76-1-F 10 LF 5 in 418A-WMSL-540-001 Sheet 6B (FMMR Inner Bottom) Piping section can be isolated by spectacle flange in AMMR and FT-V-4-48-16 AMMR (5-52-01-E) F/O Transfer Piping to 5-76-1-F 10 LF 5 in 418A-WMSL-540-001 Sheet 7B (AMMR 2ND Platform) Piping section can be isolated by spectacle flange in AMMR and FT-V-4-48-16 AMMR (5-52-01-E) F/O Transfer Piping to 5-76-2-F 2 LF 5 in 418A-WMSL-540-001 Sheet 7B (AMMR 2ND Platform) Piping section can be isolated by bolted valve FT-V-4-68-4 in Port Shaft Alley and FT-V-4-48- 12 in FMMR AMMR (5-52-01-E) F/O Transfer Piping to 5-80-0-F 2 LF 5 in 418A-WMSL-540-001 Sheet 7B (AMMR 2ND Platform) Piping section can be isolated by bolted valve FT-V-4-69-2 in Port Shaft Alley and FT-V-4-48-20 in FMMR 3.6.1 Welding requirements. The Contractor must perform all welding and allied processes in accordance with SFLC Std Spec 0740. 3.6.1.1 The contactor must provide the personnel and equipment for the fire watch. 3.6.2 Nondestructive examination (NDE). The Contractor must, in the presence of the Coast Guard Inspector, perform a visual inspection and dye penetrant inspection of all new welds in accordance with SFLC Std Spec 0740, Appendix C. Submit a CFR. 3.7 Hydrostatic test. After all authorized repairs, the Contractor must hydrostatically test all new and disturbed piping and components of the Fuel Oil Stripping and Transfer system in accordance with SFLC Std Spec 0740, Appendix C, Hydrostatic Test. Ensure zero leakage from or permanent deformation of pressure-containing parts by repairing all leaks, deformations, and discrepancies. Submit a CFR. 3.8 Operational test, post repairs. After completion of work, the Contractor shall thoroughly test, in the presence of the Coast Guard Inspector and demonstrate all items or shipboard devices that have been disturbed, used, repaired, altered, or installed to be in satisfactory operating condition. Submit a CFR. NOTE Coast Guard personnel will operate all shipboard machinery and equipment. 4 (Rev-0) 3.9 Touch-up preservation. The Contractor must prepare and coat all new and disturbed surfaces to match existing adjacent surfaces in accordance with SFLC Std Spec 6310, (Touch-ups and minor coating repairs.) 4. NOTES This section is not applicable to this work item RDD/POP: 19Jun24-15Aug24
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/5057741632804baab158edf7dece700d/view)
 
Place of Performance
Address: Alameda, CA 94501, USA
Zip Code: 94501
Country: USA
 
Record
SN07068258-F 20240519/240517230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.