Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 10, 2024 SAM #8200
SOLICITATION NOTICE

34 -- Armaments airline and power outlet

Notice Date
5/8/2024 10:34:11 AM
 
Notice Type
Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
FA4800 633 CONS PKP LANGLEY AFB VA 23665 USA
 
ZIP Code
23665
 
Solicitation Number
FA480024MP0001
 
Response Due
5/13/2024 11:00:00 AM
 
Archive Date
05/28/2024
 
Point of Contact
Mandisa Peters, Phone: 7577647427, Mr Corey Powell, Phone: 7572254010
 
E-Mail Address
mandisa.peters.1@us.af.mil, corey.powell.1@us.af.mil
(mandisa.peters.1@us.af.mil, corey.powell.1@us.af.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Shut off air compressor and LOTO circuit - Bleed all air pressure off piping - Cut in a 2�x2�x3/4� copper press tee, install ball valve in the ceiling for the parts washers - Cut in a 2�x2�x1� copper press tee, install ball valve in the ceiling for the sand blaster - Take LOTO off the air compressor circuit, and turn air compressor back on - Leak check the new fittings that where installed - Fabricate support hangers in the ceiling for both air line runs - Fabricate support hangers coming down the wall for both air line runs - Run out �� copper pipe from new ball valve down to parts washer - Install ball valve, air regulator, and a hose that will connect to the parts washer - Drill hole through the block wall for the sand blaster air line - Run out 1� copper pipe from new ball valve, through the block wall and down to sand blaster - Install ball valve and tee fitting, run 2 hoses off the tee to each connection on the sand blaster - Seal up hole around the 1� copper pipe where it goes through the block wall - Drill an additional hole in the same wall for the electrical conduit - Run out conduit from panel F751_N_1PPC out through the wall and down to sand blaster - Install a 20amp receptacle for the sand blaster - Seal up hole around the conduit where it goes through the block wall - Open air valves to each machine and verify nothing is leaking - Turn power on to the receptacle and check for proper voltage
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/532201ddedf24da0a5364f2a9ab64159/view)
 
Place of Performance
Address: Langley AFB, VA 23665, USA
Zip Code: 23665
Country: USA
 
Record
SN07057237-F 20240510/240508230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.