SOURCES SOUGHT
65 -- AngioDynamics Pro Laser This is Not a Request for Quote
- Notice Date
- 4/23/2024 6:55:01 PM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
- ZIP Code
- 15215
- Solicitation Number
- 36C24424Q0643
- Response Due
- 5/3/2024 9:00:00 AM
- Archive Date
- 05/06/2024
- Point of Contact
- Sherrie Thompson, Contact Specialist, Phone: 215-823-5800 ext. 205831
- E-Mail Address
-
sherrie.thompson2@va.gov
(sherrie.thompson2@va.gov)
- Awardee
- null
- Description
- STATEMENT OF NEED ANGIODYNAMICS PRO LASER Description of Use: The Corporal Michael J. Crescenz VA Medical Center is in need of (1) endovenous laser treatment system and (1) infiltration pump, which is critical for use in the Interventional Radiology section. Objective The Corporal Michael Crescenz VA Medical Center (CMCVAMC) intends to procure an endovenous laser treatment system and (1) infiltration pump for the facility s Interventional Radiology department. This document highlights the technical specifications and services being requested by the facility for consideration towards purchase of an endovenous laser. Vendors under this proposal shall provide all equipment and accessories, installation services, and project management support. Minimum Technical Specifications: The endovenous laser treatment and infiltration pump system shall meet the following minimum specifications: Achieves optimal vein ablation 1470nm wavelength laser Water-specific, diode laser Targeted energy of 30-50 joules/cm Maximum power of 15 watts Easy-to-use controls Ability to track pull-back through audible alarms/sounds Ability to program the laser for specific fiber types Internal sensors to monitor settings (eg. wattage, energy output) Aiming beam has multiple modes Real-time on-screen display of settings Foot pedal Pump that provides high-speed infiltration into vessels Infiltrates up to 1,100 ml per minute, or better Vibration free unit Tubing can be easily mounted. Emergency shut off. 110v Class 4 laser Safety glasses Keys Warning signs Spare fuse(s) Test fiber(s) Remote interlock connectors Power cord 3 year warranty Optional/Value Added Features: Loaner program Multi-media card Required Interfaces: The infiltration pump must be compatible with the endovenous laser treatment unit.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/107c9be92bd5423b8d5d3db4d43a4d07/view)
- Place of Performance
- Address: Department of Veterans Affairs VA Philadelphia Healthcare System 3900 Woodland Avenue, Philadelphia 19104-4551
- Zip Code: 19104-4551
- Zip Code: 19104-4551
- Record
- SN07040424-F 20240425/240423230054 (samdaily.us)