Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 14, 2024 SAM #8174
SOLICITATION NOTICE

65 -- HistoCore AUTOCUT- KCVAMC

Notice Date
4/12/2024 12:25:49 PM
 
Notice Type
Presolicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25524Q0144
 
Response Due
4/21/2024 9:00:00 PM
 
Archive Date
04/29/2024
 
Point of Contact
Tracie Raggs, Contract Specialist, Phone: 913-946-1985
 
E-Mail Address
tracie.raggs@va.gov
(tracie.raggs@va.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
Intent: It is the intent of the Kansas City VA to purchase one automated rotary microtome to use in the preparation of tissue samples obtained from Veteran patients. Scope: The Contractor shall provide, transport, install and test all listed equipment. All products must meet all salient characteristics defined in this section. All equipment and installation must meet manufacturers and VA specifications. The Contractor shall furnish all supplies, equipment, and services for delivery and installation of the supplies and equipment. The Contractor is responsible for any missing parts and components not included in the order to carry out the installation. Training of staff in the operation and maintenance of the equipment shall be provided by the Contractor. Salient Characteristics Fully Motorized Rotary Microtome Name brand or equal: HistoCore AUTOCUT Fully Motorized Microtome or Equivalent as listed below: Automated Rotary Microtome One fully motorized microtome unit. The unit must be ergonomically designed to reduce work related injuries. The microtomes must be a two in one design concept allowing fully motorized or fully manual sectioning (the course adjustment wheel must have the ability to be manually controlled). Refurbished or previously owned units are not acceptable. Unit must provide control of automated functions through a hand pad control panel; preferably positioned either on the left or right side of the microtome to ensure ergonomic operation of the unit. The unit must have a foot pedal/electronic emergency stop function. The unit must have a coarse feed wheel ergonomically positioned to reduce fatigue while trimming. The microtomes must have an adjustable force balancing system to eliminate the risk of injury by an unbalanced object head falling into the knife. The units must have an anti-static waste tray to facilitate cleaning and improve efficiency of the staff. The unit must contain 2 in 1 blade holder for both high and low-profile blades. The unit must be able to provide rapid specimen exchange by using programmable memo positions and fast homing. At least a 1-year warranty on the unit and installation. Minimal daily, monthly, and periodic maintenance. On-site training of histology staff on completion of installation at no cost to the Government. At least one copy of the Operator s Manual and of the technical service manual.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/8d31bd11ecfa4da3a5b6ad58d8e5fe71/view)
 
Place of Performance
Address: Kansas City VAMC 4801 Linwood Blvd, Kansas City 64128, USA
Zip Code: 64128
Country: USA
 
Record
SN07029214-F 20240414/240412230045 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.