66 -- Methane Analyzer

Notice Date
4/2/2024 5:46:58 AM
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
USDA ARS SEA AAO ACQ/PER PROP STONEVILLE MS 38776 USA
 
ZIP Code
38776
 
Solicitation Number
1124832
 
Response Due
4/5/2024 2:00:00 PM
 
Archive Date
04/20/2024
 
Point of Contact
Cecilia McNamee, Phone: 9852328289
 
E-Mail Address
cecilia.mcnamee@usda.gov
(cecilia.mcnamee@usda.gov)
 
Description
The USDA ARS location at 504 University Loop Jonesboro, AR 72401 UNITED STATES is looking for a Methane Analyzer, specifically Licor LI-7700 that meets the below specifications. A Li-Cor authorized distributor is required. This requirement will ensure that devices are not counterfeit or adulterated devices, have maintained adequate storage conditions, and any warranties and service and/or preventative maintenance agreements are transferred and will be honored by Li-Cor Biosciences Statement of work The LI-7700 analyzer is part of a system solely manufactured by LI-COR Biosciences. This sensor will measure methane production from an on-farm surface water reservoir used in agricultural production. The LI-7700 will be added to the existing data collection network infrastructure managed by the Delta Water Management Research Unit. The LI-7700 Open Path CH? Analyzer makes in-situ measurements of methane density with the resolution, speed, and stability required for the eddy covariance technique. The light weight, low power design provides the instrument the ability to acquire methane density data necessary to characterize ecosystem methane flux in remote environments. The open path design eliminates the need for pumps and tubing, and does not have pressure drops, tubing attenuation, or time delays associated with other closed path systems. Standard Features: Resolution (RMS noise): 5 ppb @ 10 Hz and 2000 ppb CH4 Measurement Range: 0 to 25 ppm @ -25 �C, 0 to 40 ppm @ 25 �C Data Communication: Ethernet (up to 40 Hz) Detection Method: Wavelength Modulation Spectroscopy 2f detection Linearity: Within 1% of reading Operating Pressure Range: 50 to 110 kPa Output Bandwidth: up to 20 Hz Operating Temperature Range: -25 to 50 �C Power Requirements: 10.5 to 30 VDC Power Consumption: 8 W nominal, 16 W during cleaning cycle Dimensions: Sensor: 14.33 cm dia (5.64 inches), 82.8 cm height (32.6 inches) Optical Path: 0.5 m physical path (1.65 ft), 30 m measurement path (98.4 ft) Weight: 5.2 kg (11.5 lbs) User Interface: Windows�based software supports all setup, configuration, and calibration functions through Ethernet connection �
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/81099083c3d24681b238d53713682a5f/view)
 
Place of Performance
Address: Jonesboro, AR 72401, USA
Zip Code: 72401
Country: USA
 
Record
SN07017612-F 20240404/240402230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.