SOLICITATION NOTICE
Z -- USCG Station Houston - AC Repair
- Notice Date
- 3/28/2024 12:37:51 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- BASE NEW ORLEANS(00029) NEW ORLEANS LA 70117 USA
- ZIP Code
- 70117
- Solicitation Number
- 70Z02924QNEWO0011
- Response Due
- 4/8/2024 1:00:00 PM
- Archive Date
- 04/08/2024
- Point of Contact
- Amber Russell, Phone: 281-464-4678
- E-Mail Address
-
Amber.H.Russell@uscg.mil
(Amber.H.Russell@uscg.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- PERFORMANCE OF WORK STATEMENT 1. SCOPE OF WORK- The work is to be accomplished through the following tasks: The U.S. Coast Guard is accepting quotes for qualified individuals or firms to provide all labor, materials, and equipment necessary to repace Berthing and TV Room AC Systems at Station Houston. For system Model # PUHY-P72TJMU-A Serial # 1XW00764 the contractor shall mechanically and electrically isolate the subject machine. Recover existing refrigerant charge from within the VRF system utilizing industry standards established by the EPA. Weigh the quantity of recovered refrigerant and compare it to the manufacturer's nameplate rating; advise the customer of any deficiencies and review corrective action, if any. Disconnect interconnecting refrigerant piping from one (1) leaking condenser coil; remove the existing leaking condenser coil within the VRF condenser. Provide and install one (1) new condenser coil compatible with the VRF condenser. Perform necessary field modifications to complete the installation of one (1) new condenser coil. Remove and replace one (1) filter drier. Perform an evacuation and dehydration of the VRF system. Recharge the VRF system with previously recovered refrigerant. Initiate machine start-up and check unit operation. Log and record machine operation. Advise customer of overall machine condition and recommend additional repairs or product improvements, if any. For system AAON Model # CC-C-005-3-D-1, Serial# 201402-CHCW06404 the contractor shall mechanically and electrically isolate the subject machine. Recover existing refrigerant charge from subject equipment; weigh quantity recovered and compare to unit's manufacturer's nameplate specifications (any deficiency will be reported to customer for corrective action). Remove and replace one compressor. Remove and replace one filter dryer. Leak test all newly modified refrigerant piping. Perform evacuation and dehydration and sealed refrigeration circuit. Remove and replace one compressor contactor. Recharge unit with 11.25lbs of r410A. Initiate machine start-up and check unit operation. Log and record machine operation. Advise customer of overall machine condition and recommend additional repairs or product improvements, if any. Contractor shall provide services to recover all refrigerant in the old system for reuse or dispose of properly. Contractor shall provide separate quote for needed refrigerant to complete the work to the contracting officer. All work is to be completed in accordance with the performance work statement. This will be a firm- fixed priced purchase order awarded to the lowest bidder. This is set aside 100% for small business. All contractors must be actively registered in SAM.gov. Federal Acquisition Regulation Clauses and the Department of Labor wage rates for construction are included in this agreement and are applicable. Please Email all quotes to Amber Russell/Email: AMBER.H.RUSSELL@uscg.mil For site visits please contact:�Mr. Jason Baylor� 713-818-6726 to schedule and arrange site access. �� Location: Coast Guard Station Houston 9640 Clinton Drive Houston TX, 77029 PERIOD OF PERFORMANCE Period of performance shall be within 1 weeks of acceptance of award to allow habitability of berthing rooms. DELIVERABLES The contractor shall provide the following: All associated parts to complete the repairs. Equipment needed to complete repairs. Refrigerant needed to complete repairs. SCHEDULE.� The schedule for milestones and deliverables is given in the following table.� ITEM DESCRIPTION QTY DUE DATE 1 Complete replacement of AC system 1 NLT 1 weeks ACCEPTANCE CRITERIA �������� 7.1 The government reserves the right to witness the evaluation and repair processes. �������� 7.2 The government will review the repair work in its entirety prior to issuing approval. QUALITY ASSURANCE All work shall be developed to commercial standards. TECHNICAL REPRESENTATIVE The Technical Representative at the U.S. Coast Guard Surface Forces Logistics Center will be MKC William Lee NOTES All Government Furnished Information and work product shall remain the property of the U.S. Coast Guard and shall not be released to any third party or published without prior approval from the COR.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/cf74a5e6fa66460c8bd38408fb2be136/view)
- Place of Performance
- Address: Houston, TX 77029, USA
- Zip Code: 77029
- Country: USA
- Zip Code: 77029
- Record
- SN07012433-F 20240330/240328230042 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |