SOURCES SOUGHT
36 -- Sources Sought for Automatic Tank Gauge (ATG)
- Notice Date
- 3/14/2024 2:34:45 PM
- Notice Type
- Sources Sought
- NAICS
- 333914
— Measuring, Dispensing, and Other Pumping Equipment Manufacturing
- Contracting Office
- NAVFACSYSCOM PACIFIC JBPHH HI 96860-3134 USA
- ZIP Code
- 96860-3134
- Solicitation Number
- N6274224ATG
- Response Due
- 3/15/2024 8:00:00 PM
- Archive Date
- 03/30/2024
- Point of Contact
- Katie A. Johnson, Phone: 8085976194, Erik S. Torngren, Phone: 8084746476
- E-Mail Address
-
katie.a.johnson27.civ@us.navy.mil, erik.s.torngren.civ@us.navy.mil
(katie.a.johnson27.civ@us.navy.mil, erik.s.torngren.civ@us.navy.mil)
- Description
- Notice of intent to use a brand name product.� The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide Automatic Tank Gauges.� The products must have equal performance and listing/approval requirements as the Honeywell ENRAF Servo Gauge Model 854 ATG. FY24 Project P-6003/AJJY246003 Republic of Singapore Air Force (RSAF) Pump House and Fuel Storage, North Ramp, Andersen Air Force Base, Guam requires two (2) Automatic Tank Gauge with the following characteristics: Safety certification: TUV certified for Safety Integrity Level (SIL) 2 (in single configuration). Method of level sensing: ATG must be a servo type gauge with floating displacer. Level measurement accuracy: Measuring accuracy level of less than 1.25 mm. Temperature corrected volume accuracy: Correct volume accuracy of less than or equal to 0.1 percent. Density measurement accuracy: Density accuracy of less than or equal to 1 percent. Temperature measurement accuracy: Temperature measuring accuracy to less than 0.56 �C. Operating pressure: Operating pressure up to 600 kPa. Enclosure rating: Ingress protection must be at minimum IP65 (NEMA 4X). ATG must integrate density and free water interface level measurement. Display: Local LCD display consisting of 2 lines with 16 characters per line. Output signal: Analog output must be 4-20 mA. Hazardous area classification: ATG must be explosion proof and IECEx approved. This notification is for market research purposes only to identify if other potential sources of supply can meet the requirements of the Government.� This is not a request for proposals, quotes, or an invitation for bid. �The intent of this notice is to identify other potential sources of this product. To be considered, please submit detailed technical data in order for the Government to conduct a comprehensive evaluation of your product to ensure compatibility with the existing system. �In accordance with FAR 15.201(e), a response to this notice is not an offer and cannot be accepted by the Government to form a binding contract. �The responder is solely responsible for the information it submits and any associated costs. �The Government reserves the right to disregard any submittal that is incomplete or vague.� Please do not submit company brochures. Please submit complete information by electronic mail to Ms. Katie Johnson at katie.a.johnson27.civ@us.navy.mil no later than 15 March 2024 at 5:00 p.m. H.S.T. �Information received after the due date/time will not be considered. �Any information provided to the Government in response to this Request for Information (RFI) will become U.S. Government property and will not be returned. �All proprietary or classified information will be treated appropriately.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/88bd1528720348ef89d0a7577cf329d9/view)
- Place of Performance
- Address: GU, USA
- Country: USA
- Country: USA
- Record
- SN06997960-F 20240316/240314230057 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |