SOLICITATION NOTICE
C -- AE: FTQW 221012 - Repair Waste Water Treatment SCADA System
- Notice Date
- 3/12/2024 1:42:43 PM
- Notice Type
- Presolicitation
- NAICS
- 541330
— Engineering Services
- Contracting Office
- FA5004 354 CONS PK EIELSON AFB AK 99702-2200 USA
- ZIP Code
- 99702-2200
- Solicitation Number
- FTQW221012
- Response Due
- 3/20/2024 3:00:00 PM
- Archive Date
- 04/04/2024
- Point of Contact
- Camden Chan, Phone: 9073773485, Elias Campos, Phone: 9073773567
- E-Mail Address
-
camden.chan@us.af.mil, elias.campos.1@us.af.mil
(camden.chan@us.af.mil, elias.campos.1@us.af.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Q&A: Can you clarify the scope required for the Geotechnical Engineer?� The described scope of work does not seem to require this discipline. For clarification there will be no requirement to have Geotechnical Engineers on the Team Composition. Can you confirm whether a �SE� license is required for the Structural Engineer?� For this type of facility a Civil Engineer �CE� seems allowable. For Clarification there will also be no Structural Engineeer on the Team Composition and that is correct a Civil Engineer is allowable. Are Existing P&ID� drawings available for the plant? There are no existing P&ID drawings for the plant. Will the project modify any of the existing WWTP processes? This project will not modify existing processes Will new P&ID drawings be required in the design deliverables? It states in Section 1.03 C of the SOW that a new P&IDs are required. Does the project include ADEC permitting? Since the poject doesn't involve changes to the plant's discharges, it shouldn't require any amendments to Eielson's permit. is there a page limit for Section H of the response? For section H of the response the maximum amount of pages is 10. RPR WWTP SCADA - FTQW 221012 Notice to Offeror(s)/Supplier(s): Funds are not presently available for this effort. No award will be made under this pre-solicitation until funds are available. The Government reserves the right to cancel this notice, either before or after the closing date. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs. This notice is a solicitation for Architect and Engineering services to be performed on Eielson AFB, Alaska. Please refer to the attached Project Attachments for further instructions/details. Please be sure to email both the Primary and Secondary POC's for any questions(As directed above)/ SF 330 submissions (General Information)**
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/714d42d7e93c43369b92c84a764d342f/view)
- Place of Performance
- Address: Eielson AFB, AK 99702, USA
- Zip Code: 99702
- Country: USA
- Zip Code: 99702
- Record
- SN06993549-F 20240314/240312230047 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |