SOURCES SOUGHT

J -- Uninterruptable Power Supply (UPS) Preventive Maintenance Clarksburg (VAMC) 540- 24-2-5050-0599

Notice Date
3/6/2024 6:06:40 AM
 
Notice Type
Sources Sought
 
NAICS
541990 — All Other Professional, Scientific, and Technical Services
 
Contracting Office
245-NETWORK CONTRACT OFFICE 5 (36C245) LINTHICUM MD 21090 USA
 
ZIP Code
21090
 
Solicitation Number
36C24524Q0335
 
Response Due
3/13/2024 7:00:00 AM
 
Archive Date
05/12/2024
 
Point of Contact
Bill Pratt, Contract Specialist, Phone: 410-642-2411 ext. 22230, Fax: Service Team 1
 
E-Mail Address
Billie.Pratt@va.gov
(Billie.Pratt@va.gov)
 
Awardee
null
 
Description
SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for information/sources sought notice in order to identify vendors that are interested in and capable of providing contractor services for the provision of labor and material to provide semi - annual preventive maintenance and testing for facility Uninterruptable power supply (UPS) at six (6) calendar month intervals. PLACE OF PERFORMANCE: Louis A. Johnson VAMC 1 Medical Center Dr Clarksburg WV 26301 DESCRIPTION OF WORK: Contractor will provide all resources necessary material, equipment, labor, & supervision, to perform preventive maintenance and testing for facility Uninterruptable power supply (UPS). Contractor shall propose a preventive maintenance (PM) procedure for VA review and approval. The proposed PM process shall minimally include the following: Visual inspection of equipment for cracks, leaks, or physical deterioration. Thermal scan of equipment and conductor connection. Verification of appropriate torque on all conductor connections. Conduct operational test to include battery run down time. Testing of UPS bypass switch (if equipped) for proper operation and isolation. Inspection and cleaning of all internal UPS fans or cooling components. Cleaning of the internal components of the UPS housing to include conductor connections. Contractor shall provide a written report of all work completed, observed conditions related to UPS operation. Any observations related to remaining service life of UPS system or individual cells or components should be identified. Contractor access to equipment will be provided throughout an active hospital setting. Information technology (IT) equipment may require shutdown by VAMC personnel prior to allowing contractor access to connected UPS. Shutdown of IT equipment may delay contractor progress between locations. Delay in work progress should be anticipated as an operational need of the government facility. Existing UPS Information: Liebert Model: N Power   MFR s ID: MX Part #: 37SA080C0C6BA27 Serial #37-5686 Module Input: 3 Phase (3+N+G wire) VAC:208 (210AMPS) (60HZ) Input KVA: 76 (KW:70) Input Filter:10% Short Circuit Current Rating: 65KA Output: 3 Phase (3+N+G wire) VAC:120/208 (222AMPS) (60HZ) Output KVA: 80 (KW:64) Installed Options: Part # s 22-812511-01 (10% Filter) 370P000MBB2 (Multi Batt) 370P000ICI2 (OC-DI) 370P0000PS2 (Kit Power) 370P000PRB2 (OC-DO) Existing Battery Cabinet Information 174 Amps DC, Max. at 391 Volts DC Model #: 37BP080XWXCBNR Serial #: 3T00005193 Battery #: HX500 Weight: 5275 Ref. drawings: 521817 PERIOD OF PERFORMANCE: Contract period of performance is one twelve (12) month base period. The government at its sole discretion may elect to extend this contract for a total of four (4) additional twelve (12) month option periods. SERVICE CONTRACT LABOR STANDARDS: The Service Contract Labor Standards apply to this contract. Contractor will be responsible for compliance with the Service Contract Labor Standards and determining which of its workers are performing on or in connection with the contract and properly segregating their hours for purposes of pay and recordkeeping. The Department of Labor s Wage Determination is provided as an attachment; it specifies the minimum wages and fringe benefits for workers performing on or in connection with this contract. Interested & Capable Responses:  NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Louis A. Johnson VA Medical Center. Please respond to this RFI/Sources Sought 36C24524Q0335 with your: Business name (including Unique Entity ID (SAM.gov)   Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and   Person of contact (including telephone number & email address).    Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities.   Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS)  Brief Summary of categories of services that your company can/cannot provide.  Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable)  Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response:    Do you intend to self-perform this effort?  If you are located outside the immediate area, how will you self-perform?  Or do you intend to subcontract work under this contract?  If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?    Response Instructions:  Responses must be submitted by 10:00 AM (ET) March 13th, 2024. Responses to the information requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov. This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.).  VA assumes no responsibility for any costs incurred as a result of a vendor s attendance to the Site-Visit nor the preparation of responses submitted as a result of this notice. Bill Pratt Contract Specialist VHA, NCO 5 Billie.Pratt@va.gov
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/38bb5efceae6461082aa71d49391109a/view)
 
Place of Performance
Address: Department of Veterans Affairs Louis A. Johnson VA Medical Center 1 Medical Center Drive, Clarksburg, WV 26301, USA
Zip Code: 26301
Country: USA
 
Record
SN06988375-F 20240308/240306230053 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.