SOURCES SOUGHT

66 -- 66--Reverse Osmosis System

Notice Date
2/27/2024 9:26:46 AM
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
OFFICE OF ACQUISITON GRANTS SACRAMENTO CA 95819 USA
 
ZIP Code
95819
 
Solicitation Number
140G0324Q0086
 
Response Due
3/5/2024 5:00:00 PM
 
Archive Date
03/31/2024
 
Point of Contact
Huot, Tracy, Phone: 9162789330
 
E-Mail Address
thuot@usgs.gov
(thuot@usgs.gov)
 
Description
The U.S. Geological Survey (USGS) is conducting market research to determine the availability of qualified businesses capable of providing a Reverse Osmosis System as described in the required features and specifications below. This sources sought announcement is not a request for quote or proposal and the Government is not committed to award of a purchase order or contract pursuant to this announcement. The information resulting from this market research is simply for planning purposes to assist the Government in determining its acquisition strategy. The Government will not pay for any costs incurred in the preparation of information for responding to this notice. The North American Industry Classification System (NAICS) code - 334516 Analytical Laboratory Instrument Manufacturing, with the associated size standard of 1,000 employees apply to this announcement. All responsible sources may submit a brochure and/or technical specifications detailing the ability of meeting the required features and specifications included with this announcement. Please no phone calls. Responses to this announcement shall only be accepted through electronic mail addressed to thuot@usgs.gov and must be uploaded and received in their entirety no later than 03/05/2024 at 1700 PS. Responses submitted by hardcopy or the SAM web portal shall not be accepted or considered. Required features and specifications: (Price must include being installed) -integral 350-liter storage tank, -in-line UV treatment, -in-line filtration (0.2um), -deliver 200 liters per hour of primary grade water to the tank and supply purified water up to ultra-pure water quality through laboratory plumbing. -utilize the UV treatment, 0.2um filtration and SDI treatment within the distribution loop to maintain post RO water quality & guarantee water quality within the laboratory. -user initiated automatic sanitation. -user definable monitoring alarms for system operations -ability to connect system to Center computer system to monitor system remotely. System Performance Standards: -Inorganics: up to 18.2 MegOhm-cm -Inorganics with no SDI cylinders: up to 98% rejection -Organics: with no SDI cylinders >99% rejection (>100 Dalton) -TOC: <500 ppd -Bacteria: <10 CFU/m -Distribution: 38 Liters/minute
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/ef66c3540fd6472c820fd0307754fb29/view)
 
Record
SN06978925-F 20240229/240227230053 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.