SPECIAL NOTICE
N -- W9127N23R0002 - Notice of Intent to Limit Competition
- Notice Date
- 2/7/2024 2:02:11 PM
- Notice Type
- Special Notice
- NAICS
- 237990
— Other Heavy and Civil Engineering Construction
- Contracting Office
- W071 ENDIST PORTLAND PORTLAND OR 97204-3495 USA
- ZIP Code
- 97204-3495
- Solicitation Number
- W9127N24R0002
- Response Due
- 2/21/2024 3:00:00 PM
- Archive Date
- 03/07/2024
- Point of Contact
- Andrea Smothers, Andrew Sprys
- E-Mail Address
-
andrea.k.smothers@usace.army.mil, andrew.j.sprys@usace.army.mil
(andrea.k.smothers@usace.army.mil, andrew.j.sprys@usace.army.mil)
- Description
- THIS IS A SPECIAL NOTICE PREPARED IN ACCORDANCE WITH FEDERAL ACQUISITION REGULATION (FAR) SUBPART 5.2 �SYNOPSES OF PROPOSED CONTRACT ACTIONS� NAICS 237990, Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables Response Deadline: 21-FEBRUARY-2024 The U.S. Army Corps of Engineers (USACE), Portland District�(NWP)�intends to negotiate/award a firm-fixed price (FFP) construction contract to include the following brand name or sole source requirements. REASON FOR OTHER THAN FULL AND OPEN COMPETITION: 10 United States Code 3204(a)(1) as implemented in Federal Acquisition Regulation 6.302-1(a)(2), the supplies or services required by the agency are available from only one or a limited number of responsible sources, and no other type of supplies or services will satisfy agency requirements. The purpose is to obtain supplies at the required level of quality because the supplies or services are unique or highly specialized. REQUIREMENTS: Swagelok Fittings Emerson MagTech LTM-350 series direct insertion magneto strictive level transmitter Emerson MagTech LTM-350 series gauge mount (~3ft long) Emerson MagTech LTM-350 series gauge mount (~18ft long) Emerson Rosemount 5300 Guided Wave Radar level sensor (~17 ft long) Emerson MagTech LTM-350 series dual-chamber gauge mount magnetostrictive level transmitter Emerson Rosemount 5300 Guided Wave Radar level sensors Emerson Rosemount 4600 series pressure/temperature transducer Emerson Rosemount 114C series thermowell Emerson Rosemount 214C series resistance temperature detector Emerson Rosemount 751 series remote displayCisco Catalyst 9300-48S-A Managed Server Rack Switches Cisco STACK-T1-50CM Data Stacking Cable for Catalyst Switches Cisco CAB-SPWR-30CM Power Stacking Cable for Catalyst Switches Allen Bradley PLC Hardware and/or Software by Rockwell Automation Perle SR-1110-SFP Din Mounted Media Converters Perle PSFP-1000D-M2LC2 Fiber SFP Module Background: The Dalles Dam is located in The Dalles, Oregon. The Dalles Dam (TDA) is a concrete gravity run-of-the-river dam spanning the Columbia River, two miles east of the city of The Dalles, Oregon, United States. It joins Wasco County Oregon, with Klickitat County Washington, 300 miles upriver from the mouth of the Columbia River near Astoria, Oregon. The project is designed to improve the monitoring of the amount of oil that could be released into the Columbia River. Its main objective is to minimize the oil release. Project Scope. There are approximately 400,000 gallons of oil at the TDA powerhouse. Oil monitoring measures currently consist primarily of visual observations of sight glasses, observations of oil leaks on and around equipment, and purchase and disposal records of lubricants. The Federal Government agreed to develop and apply an Oil Accountability Plan (OAP) pursuant to the August 2014 settlement agreement with Columbia Riverkeepers.� The OAP is intended to account for oils and greases used, including the oils and greases used in turbines, wicket gate bearings, and fish-way equipment. This project would improve the ability to consistently and reliably account and monitor leakage of oils through automated systems and greatly increase the timeliness of level monitoring. It would also assist in fulfilling the requirements of the Portland Districts Standing Environmental Policy 200-1, Oil Accountability while significantly reducing the O&M costs to do so. The purpose of this project is to improve accuracy and increase automation of instrumentation to account for oil in oil-filled equipment, bulk storage containers, and high risk equipment. It is also to aid in the identification of oil leaks as early as possible and fully account for potential leaks. The Government intends to solicit for this project on or around MAY 2024. Currently, a solicitation does not exist. All responsible sources may submit a capability statement, proposal, or quotation, which shall be considered by the agency. *NO PHONE INQUIRIES, PLEASE. CAPABILITY STATEMENT SUBMISSION REQUIREMENTS (PLEASE REVIEW ALL BELOW) Point of Contact name, email address and phone number, CAGE code and SAM UEI number (if available); In the event that the organization is a small business, please state the category of small business, such as 8(a), HUBZone, SDVOSB/VOSB, Women-Owned Small Business. The Government will evaluate the capabilities of an interested party based on their ability to provide the above listed items, with all original warranties, support, terms, and conditions. Send responses, labeled as �W9127N24R0002 Limited Sources, TDA Oil Accountability Measures� to the following: andrea.k.smothers@usace.army.mil and andrew.j.sprys@usace.army.mil
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/f1973d21d7ba40e8b8961dbd395018db/view)
- Place of Performance
- Address: The Dalles, OR 97058, USA
- Zip Code: 97058
- Country: USA
- Zip Code: 97058
- Record
- SN06957671-F 20240209/240207230044 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |