Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 23, 2023 SAM #8061
SOLICITATION NOTICE

X -- General Services Administration: Office Space-Office Lake Charles, LA

Notice Date
12/21/2023 10:30:51 AM
 
Notice Type
Presolicitation
 
NAICS
531190 — Lessors of Other Real Estate Property
 
Contracting Office
PBS R7 OFFICE OF LEASING FORT WORTH TX 76102 USA
 
ZIP Code
76102
 
Solicitation Number
2LA0242
 
Response Due
1/12/2024 3:30:00 AM
 
Archive Date
01/27/2024
 
Point of Contact
Michael Noye, Phone: 8178508107
 
E-Mail Address
michael.noye@gsa.gov
(michael.noye@gsa.gov)
 
Description
P Presolicitation Notice/Advertisement GSA Public Buildings Service U.S. GOVERNMENT General Services Administration (GSA) seeks to lease the following space: State: LA City: Lake Charles Delineated Area: City of Lake Charles Minimum Sq. Ft. (ABOA): 3,652 Maximum Sq. Ft. (ABOA): 4,199 Space Type: Office Parking Spaces (Total): 7 Parking Spaces (Surface): Surface7 Parking Spaces (Structured): 0 Parking Spaces (Reserved): 7 Full Term: 10 years Firm Term: 8 years Option Term: N/A Additional Requirements: AGENCY UNIQUE REQUIREMENTS � All space must be contiguous, and preferably on the 2nd floor or higher. Space on the first floor will be considered only when no other space is available, or if deemed appropriate by Tenant. First floor spaces require additional security measures. � If the exterior skin of the building is not of substantial construction as determined by Tenant Security (e.g., concrete, filled CMU) and does not meet Tenant�s forced entry protection requirements, interior assembly of perimeter walls must be constructed in accordance with Wall Type A7 specifications. � All exterior perimeter windows must have fragment retention film, except at SCIF Rooms, which must have film rated for RF/IR shielding and blast film, as specified within the POR. � All perimeter windows less than 18�-0� from grade or accessible platform (e.g., air conditioners, fire stairs, adjacent roofs, ledges, or windows) must have forced entry protection such as man bars or security screening. Assessment of accessible platform(s) will be determined by Tenant Security. � Design of workstation must ensure computer monitors do not face exterior windows. � Roofs less than 18�-0� from grade or accessible 11/2022 platform must meet the same forced entry protection and sound attenuation requirements as the building�s perimeter walls. Metal roofs less than 18�-0� from grade or accessible platform must be 18-gauge or greater to meet the same forced entry protection and sound attenuation requirements as perimeter walls. � Metal structure buildings that will have an �Open Storage Secure� security posture must have the secured perimeter constructed to meet forced entry protection requirements, Wall Type A7, or approved equivalent by Tenant and CO. � If the space and/or building are of wood joist construction or in an historical building, additional security measures will be required and must be approved by Tenant Security. � Skylights must be removed or secured against forced entry, blast, and visual observation. � Where Tenant space adjoins another building, tenant, or public areas, perimeter walls of Tenant space must be constructed slab-to-slab in accordance with the diagram for Wall Type A7. All conduits, backboxes, and electrical devices on Tenant demising wall must be surface-mounted on the secure side. Surface mounting is not required if non-secured side of Wall Type A7 is available for inspection by Tenant. � No telephone lines, data lines, electrical service, plumbing service, or ducts other than that required for Tenant are permitted to pass through the space, except with specific approval from Tenant and CO or when routed through building space (such as electrical or telephone closets dedicated to that use). All wiring, conduits, and pipes running through the space and not serving Tenant�s needs must be removed and/or rerouted. If wiring, conduits, and pipes must not be removed and/or rerouted, they must be enclosed with a construction assembly compliant to secure wall requirements. � Future ceiling, floor slab, or demising wall penetrations through Tenant�s secured perimeter will not be permitted. � If floor slab does not extend to the skin of the building, additional security measures will be required to meet forced entry protection, Tenant Security sound attenuation requirements, and RF requirements. � The office will be provided with file safes weighing between 850 lbs and 1,000 lbs each. Although safes will be dispersed throughout the office, floor load of the proposed site must be capable of supporting this additional weight. Tenant will provide Lessor and Lessor�s team with quantity and approximate location of safes. � Tenant�s regular business hours are 7:00 AM to 5:30 PM; however, 24-hour access to the space and any provided elevator service must be available 365 days per year. � One (1) elevator must be provided with override 11/2022 control. If the office is located on the 6th floor or above, elevator must be on emergency power. � Proposed site must not be within 640�-0� of any facilities identified by ISC as �hazardous materials transportation/ storage facilities.� � Hazardous locations include facilities with potential environmental threats (e.g., fuel storage areas, gas stations, chemical manufacturing facilities, and railroad lines transporting hazardous material). � Special consideration should be given to exclude sites located near hazardous areas, such as bulk storage sites (e.g., hazardous materials storage sites, water purification centers, above-ground fuel storage, and rail yards). � It is preferred that the proposed facility not be located near �Low Risk Facilities� (e.g., day care centers, senior centers, schools, hospitals, and religious/rehabilitation/social service centers). � Proposed facility must not be located within 400�-0� of public defenders, ICE, probation offices, IRS, universities, other businesses or facilities, deemed unacceptable by Tenant Security for safety purposes. This requirement may be waived by Tenant Security if no other facility is deemed acceptable. In those cases, enhanced security requirements may be necessary. � Proposed Tenant spaces or facilities within 400�-0,� or adjacent to facilities associated with foreign powers identified in Tenant's National Security Threat List, will not be considered. � For proposals of space in existing buildings, standoff distance must be provided from the curb line or nearest point accessible by a vehicle to the fa�ade of the building to house the Tenant office. Refer to Appendix 3 of this POR. � Crawl space below or attic areas above the space proposed for Tenant�s occupancy is not preferred, and will require additional security measures. Agency Tenant Improvement Allowance: Existing leased space: $50.46 per ABOA SF Other locations offered: $50.46 per ABOA SF Building Specific Amortized Capital (BSAC): Existing leased space: $25.00 per ABOA SF Other locations offered: 25.00 per ABOA SF Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease. A fully serviced lease is required. Offered space shall not be in the 1-percent-annual chance/0.2- percent-annual chance floodplain (formerly referred to as 100-year/500-Year floodplain). 11/2022 Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR). ). For more information, visit: https://acquisition.gov/FAR- Case-2019-009/889_Part_B. Expressions of Interest Due: 1/12/2024 Market Survey (Estimated): 1/25/2024 Occupancy (Estimated): 5/1/2025 Send Expressions of Interest to: Name/Title: Michael Noye, Lease Contracting Officer Email Address: Michael.noye@gsa.gov Government Contact Information Lease Contracting Officer Michael Noye, michael.noye@gsa.gov 817 201- 9326 Leasing Specialist Gean Collier, emma.collier@gsa.gov
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/5feb45152d6c41e087cdba76bce401a1/view)
 
Place of Performance
Address: Fort Worth, TX 76102, USA
Zip Code: 76102
Country: USA
 
Record
SN06919735-F 20231223/231221230046 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.