SOURCES SOUGHT
48 -- Limitorque Valve Actuators Replacement
- Notice Date
- 11/29/2023 11:46:19 AM
- Notice Type
- Sources Sought
- NAICS
- 333995
— Fluid Power Cylinder and Actuator Manufacturing
- Contracting Office
- FA9101 AEDC PKP PROCRMNT BR ARNOLD AFB TN 37389-1332 USA
- ZIP Code
- 37389-1332
- Solicitation Number
- FA9101-LVAR
- Response Due
- 12/7/2023 10:00:00 AM
- Archive Date
- 12/22/2023
- Point of Contact
- Leslie McGowan, Phone: 931-454-4425, Haley Smith, Phone: 931-454-4406
- E-Mail Address
-
leslie.mcgowan@us.af.mil, haley.smith.10@us.af.mil
(leslie.mcgowan@us.af.mil, haley.smith.10@us.af.mil)
- Description
- CONTRACTING OFFICE ADDRESS: AFTC/PZIA (Arnold) Attn: Leslie R. McGowan 100 Kindel Drive Suite A332 Arnold AFB, TN 37389-1332 SOURCES SOUGHT NOTICE The Air Force Test Center�s Installation Contracting Division (AFTC/PZI) at Arnold Air Force Base (AFB), TN is seeking sources to replace and install torque limiting valve actuators at Arnold Engineering Develoment Complex�s (AEDC) White Oak, Tunnel 9, 10905 New Hampshire Ave, Silver Spring, MD� 20903-1050 in accordance with (IAW) Attachment 1 � Technical Requirements. DISCLAIMER: THIS SOURCES SOUGHT NOTICE IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS ANNOUNCEMENT IS STRICTLY VOLUNTARY. INTRODUCTION: AEDC�s Tunnel 9 limtorque valve actuators are aging and in need of replacement to maintain current and future mission requirements.� The scope of this effort is to provide new torque limiting actuator drives for 60� gate valves in use at Tunnel 9. �Newly supplied drives will be drop-in replacements for the existing limitorque drives on site S/N 123581, ad S/N 123582 which were manufactured by Flowserve. �New valve actuators will fit the existing mounting system and actuation mechanism without modification to the valve or additional engineering effort to make a custom actuator fit. �The new actuator should match the valve stem gear pitch and size without modification to the existing valve. The valve actuator shall meet the specification detailed below, additional details may be found in Attachment 1 - Technical Requirements: Valve Actuator Specification Valve:��60"" gate Actuation:�Linear�� - Vertical Start Torque:��60 ft-lb Run Torque:��12 ft-lb RPM:��1720 V34 Motor:��230/460 Phase:��3 HZ:��60 This is a Sources Sought Notice to determine the availability and technical capability of small and large businesses to meet the Government�s requirement to manufacture and install two limitorque valve actuators for Tunnel 9 IAW Attachment 1 � Technical Requirements. NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE: The anticipated North American Industry Classification System Code (NAICS) for this requirement is 333995, Fluid Power Cylinder and Actuator Manufactoring, with the corresponding business size standard of 800 employees, and Product Service Code 4810, Valves, Powered. SUBMISSION DETAILS: Responses should include: �Company Information: Company name, company address, and telephone number and e- mail address of company point of contact.Business size under NAICS code 333995. �System for Award Management (SAM) Unique Entity Identifier (UEI) Number. �Indicate if there any technical requirements that are too restrictive or not traditionally available in the marketplace. Also indicate if any of the technical requirements should be changed based on industry standards. �Comments/feedback on Attachment 1- Technical Requirements. �Please provide an estimated Period of Performance (in weeks) that it would take to complete the work IAW Attachment 1 � Technical Requirements The capability package must be clear, concise, and complete. The Air Force is under no obligation to provide feedback to a company, or to contact a company for clarification of any information submitted in response to this request. Submission: Provide your intent/response no later than 12:00 PM Central Time (CT) on 7 December 2023, via email to Ms. Leslie McGowan at leslie.mcgowan@us.af.mil and Ms. Haley Smith at haley.smith.10@us.af.mil. �Verbal responses will NOT be accepted. Proprietary information and trade secrets, if any, must be clearly marked on all materials. All information received that is marked Proprietary will be handled accordingly. Please be advised that all submission become Government property and will not be returned. All government and contract personnel reviewing sources sought responses will have signed non-disclosure agreements and understand their responsibility for proper use and protection from unauthorized disclosure of proprietary information as described 41 USC 423. The government shall not be held liable for any damages incurred if proprietary information is not properly identified. Attachment(s): 1. Technical Requirements
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/04de9249c3924c7ea9a523136caa5652/view)
- Place of Performance
- Address: Silver Spring, MD 20903, USA
- Zip Code: 20903
- Country: USA
- Zip Code: 20903
- Record
- SN06898189-F 20231201/231129230059 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |