Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 18, 2023 SAM #8026
SOLICITATION NOTICE

45 -- FCC Hazelton - Water Heating System - PRODUCT ONLY

Notice Date
11/16/2023 11:17:51 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
USP HAZELTON BRUCETON MILLS WV 26525 USA
 
ZIP Code
26525
 
Solicitation Number
15B12124Q00000002
 
Response Due
11/27/2023 11:00:00 AM
 
Archive Date
12/12/2023
 
Point of Contact
Kelly Brown, Phone: 3043795156, Andrea Burke
 
E-Mail Address
k1roberts@bop.gov, ax2burke@bop.gov
(k1roberts@bop.gov, ax2burke@bop.gov)
 
Description
FCC Hazelton requires a quantity of 4 each indirect plate and frame water heater plus 4 each pumps to accompany the water heaters. �Vendors are required to have active SAM.Gov registration and to provide their UEI. A signed SF1449 must be submitted to be considered received. This requirement is for product ONLY. All quotes and bids are required to be submitted to Kelly Brown, Supervisory Contract Specialist with FCC Hazelton at k1roberts@bop.gov (Note: that is a number one after the K) AND HAX-ProcurementProp-S@bop.gov. Quotes must be valid for at least 30 days after close of bids on November 27, 2023 at 2 PM EDT. Specific product requirements below and example spec sheets attached. Indirect Plate And Frame Water Heater: (4) Dimensions cannot Exceed: 63� Height Max; 22� Width max; 61� Base Length � MUST FIT THROUGH STANDARD 36� door. Product should not exceed 1200 lbs � Lite Weight Preferred FEATURES: ASME DOUBLE WALL HEAT EXCHANGER��������������������������������������������� � 316L Stainless Steel � 150 psi Working Pressure DIGITAL DISPLAY � DHW Set Point Range 90�F to 180�F ADVANCED TEMPERATURE CONTROL MODULATING CONTROL VALVE SCALE REDUCING PUMP AUTOMATIC AIR VENT ASME TEMPERATURE & PRESSURE RELIEF VALVE � 210�F and 150 psi ADJUSTABLE HIGH LIMIT WYE STRAINERS - DOMESTIC PIPING AND BOILER PIPING ISOLATION VALVES - DOMESTIC PIPING�AND BOILER PIPING MODBUS COMMUNICATION WARRANTY � 5-Year limited warranty/1-Year limited parts � Warranty for product only without services requirement SUGGESTED SPECIFICATION The Indirect Plate and Frame shall be constructed of a 316 stainless steel plate with EPDM gaskets. Maximum unit dimensions shall be: Length ___61_inches, Width ___22___inches and Height __63______ inches. The Indirect Plate and Frame shall be a double wall. The plate and frame shall be constructed in accordance with the ASME Boiler and Pressure Vessel Code requirements, stamped and registered with the National Board of Boiler and Pressure Vessel Inspectors� The Indirect Plate and Frame shall have a 150 psi working pressure and be supplied with an ASME temperature and pressure relief valve. Standard equipment shall include Wye Strainers, Isolation Valves, Automatic Air Vent, Scale Reduction Pump, Adjustable High Limit and drain valve The temperature control shall provide + or � 4 degrees Fahrenheit accuracy with up to a 50% change in load. Setpoint range between 90 and 180 F. Modbus communication shall be standard equipment. The modulating valve shall have a 1000 to 1 turndown. The Indirect Plate and Frame shall be suitable for use with polypropylene glycol, up to 50% concentration. The de-rate associated with the glycol will vary per glycol manufacturer. Pump: (4) Specifications must meet all below requirements for pump withsystem control and monitoring key Conditions of Service Flow: 130 US GPM Head: 32 ft Efficiency: 68.6 % Liquid: Water Temperature: 60 �C NPSH required: ft Pump Data Specific Gravity: 0.985 Maximum operating pressure: 12 bar Liquid temperature range: -10 .. 110 �C Maximum ambient temperature: 40 �C Flange standard: GF Pipe connection: GF65 Product number: On request Motor Data P1 max: 29 .. 1385 W Mains frequency: 60 Hz Enclosure class: X4D Insulation class: F ADDITIONAL INFORMATION: Domestic inlet temp Set point. DHW set point 90 to 180 degrees. GPH for all units together or for each if separated. GPH is for each unit. Each system will supply at minimum hot water to 64-cells, 10-showers, 2-mop closet and 1-staff restroom. Boiler water entering temp 160-180 degrees. Boiler water Leaving temp 120-140 degrees BTU I am looking for specifics on this. -These units are in use 24/7-365 if that helps. For singled cell showers, 10 to be used at a time with a maximum of up to 128.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/5ef14ca99f794627898bb49a2451b563/view)
 
Place of Performance
Address: Bruceton Mills, WV 26525, USA
Zip Code: 26525
Country: USA
 
Record
SN06887563-F 20231118/231116230044 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.