MODIFICATION

Z -- 523-17-008 Boiler Plant AST Containment

Notice Date
11/15/2023 10:54:00 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
 
ZIP Code
04330
 
Solicitation Number
36C24124B0015
 
Response Due
12/18/2023 10:00:00 AM
 
Archive Date
02/16/2024
 
Point of Contact
Alexis C Duda, Contract Specialist
 
E-Mail Address
Alexis.Duda@va.gov
(Alexis.Duda@va.gov)
 
Awardee
null
 
Description
This solicitation is an invitation for bid for project 523-17-008 Boiler Plant AST Containment at the VAMC, Jamaica Plain. The Jamaica Plain VAMC has completed an inspection of two (2) 40,000-gallon diesel ASTs and containment systems, and one (1) 11,410-gallon liquid nitrogen AST. The inspection identified several conditions of concern for the diesel ASTs and recommended that associated repairs be completed. Work is to be performed at VA Boston Healthcare System Jamaica Plain in accordance with the Statement of Work (SOW), Specifications, Drawings, Federal, State, and Local Codes. Boiler Plant Building #5 Scope: The VA had a third party conduct an inspection of our ASTs that revealed the following issues: Conditions Identified/Recommendations: Concrete Foundation/Floor Issues/Dike Containment- Overall structural foundation is in good condition per visual inspection, however, top coating at various areas is cracked, thus, recommend these areas be recoated to avoid water penetration, accordingly. Upper Left Rear Dike-Wall Issue- There is a visible separation of upper corner section of wall system, thus, recommends it be repaired and sealed. Tank Labeling Issues- Recommend additional labeling for tank is put on tank to identify product properly and clearly in tank and reflect tank numbers as noted above. Corrosion/Painting Issues- Recommend that for various smaller sections/areas of steel components (for tank and piping) that are starting to show signs of corrosion are repainted. However, it should be noted that there were no visible signs of structural damage to these components as of time of this inspection. Contractor to refer to attached drawings and general requirements specifications for repair plan. All work shall be performed and executed in accordance with provided drawings, specifications, SOW, and contract documents. The Period of Performance is 180 calendar days from the issuance of the Notice to Proceed (NTP).
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/5f1149256056423aa33d78dd043dd949/view)
 
Record
SN06885586-F 20231117/231115230052 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.